General arrangement objects · DK12

AutomationDirect DK12 enclosure drip shield

In plain English

What it does

DK12 is the drawing identifier for enclosure drip shield in AutomationDirect's Enclosure Accessories collection. A drip shield forms part of the selected enclosure installation arrangement. Its mounting and overhang must be coordinated with the enclosure and the required service access.

A simple example

For example, in a microgrid installation with an enclosure installation with a separately selected top shield, use the DK12 reference to coordinate shield fixing, overhang and access to adjacent equipment. Show the neighbouring equipment and the connection route so the installer can understand the intended arrangement.

Identify DK12Coordinate enclosure drip shieldConfirm the selectedinstallation
A practical coordination sequence for this named equipment reference. It is not an electrical connection diagram.

What the drawings help you do

Use the reviewed native drawing identified as Enclosures and Wiring/Enclosure Accessories/DK12.dwg, Enclosures and Wiring/Enclosure Accessories/SSDK12.dwg for the exact physical details. Locate the named file in its original manufacturer archive. Manufacturer drawing previews are shown only when an exact approved source is available. Any illustrative 3D view is a separate concept and is not to scale; use the selected manufacturer documents for dimensions, ratings and installation details.

Drawing identity
The named manufacturer drawing used to identify the intended physical configuration.
Interface
The place where this part mounts, connects or meets another selected part.
Service space
The area needed to reach, disconnect or remove the selected equipment as instructed.

Before using this reference

  • Match DK12, the native drawing identity and the project equipment schedule.
  • Identify the compatible enclosure and shield installation orientation.
  • Coordinate shield fixing, overhang and access to adjacent equipment with neighbouring equipment.
  • Confirm the current manufacturer installation instructions, selected revision and any required mounting or clearance details.

Read the source: AutomationDirect Enclosure Accessories official CAD source

Explore the model in 3D

An original 3D illustration of this equipment type. Rotate and zoom to explore its shape. It does not represent an exact manufacturer model or dimensional layout.

AutomationDirect DK12 enclosure drip shieldIllustrative 3D · Not to scale
AutomationDirect DK12 enclosure drip shield: illustrative equipment shape, not to scale

Drag to rotate · Scroll or pinch to zoom · Original educational visualisation. Relative proportions; use the selected manufacturer drawing for dimensions.

View original CAD files and drawingsSee your whole project in 3D with Elora

What it represents

DK12 is the drawing identifier for enclosure drip shield in AutomationDirect's Enclosure Accessories collection. A drip shield forms part of the selected enclosure installation arrangement. Its mounting and overhang must be coordinated with the enclosure and the required service access.

For example, in an enclosure installation with a separately selected top shield, use the DK12 reference to coordinate shield fixing, overhang and access to adjacent equipment. Show the neighbouring equipment and the connection route so the installer can understand the intended arrangement.

Use the reviewed native drawing identified as Enclosures and Wiring/Enclosure Accessories/DK12.dwg, Enclosures and Wiring/Enclosure Accessories/SSDK12.dwg for the exact physical details. Locate the named file in its original manufacturer archive. Manufacturer drawing previews are shown only when an exact approved source is available. Any illustrative 3D view is a separate concept and is not to scale; use the selected manufacturer documents for dimensions, ratings and installation details.

How to read it

  • Keep shield fixing, overhang and access to adjacent equipment visible in the layout.
  • This reference concerns the named DK12 drawing and its enclosure drip shield role. A drawing in the same collection is not automatic evidence of compatible terminals, mounts or electrical performance.

Information to show or reference

  • Match DK12, the native drawing identity and the project equipment schedule.
  • Identify the compatible enclosure and shield installation orientation.
  • Coordinate shield fixing, overhang and access to adjacent equipment with neighbouring equipment.
  • Confirm the current manufacturer installation instructions, selected revision and any required mounting or clearance details.

A distinction that matters

This reference concerns the named DK12 drawing and its enclosure drip shield role. A drawing in the same collection is not automatic evidence of compatible terminals, mounts or electrical performance.

Sources you can follow

These public references support the explanation and provide further detail. Their graphics and downloadable files remain with their publishers.

AutomationDirect Enclosure Accessories official CAD source

Official source collection and exact native drawing identity, with the equipment role checked against native content or the narrowly defined source family.

AutomationDirect · Public reference checked 29 October 2026 · Link only

Entry JSON · Entry Markdown · Last editorial update: 29 October 2026

Put the reference into a drawing workflow.

Elora Grid helps electrical teams work with drawings, specifications and equipment information. Explore the drafting workflow or join the early-access waitlist.