IEEE / ANSI · HSW1S91

ANSI/IEEE Phase-to-neutral voltmeter selector form

IEEE-library form of phase-to-neutral voltmeter selector: this representation identifies selection among phase-to-neutral voltage measurement connections.

In plain English

What does ANSI/IEEE Phase-to-neutral voltmeter selector form mean?

This reference locates phase-to-neutral voltmeter selector in Autodesk's IEEE-oriented miscellaneous switches family. This representation identifies selection among phase-to-neutral voltage measurement connections. The meter is connected to the selected phase relative to the documented neutral or reference point. That connection differs from measuring between two phase conductors. The public library uses HSW1S91 for its horizontal representation; this is a vendor block name, not an IEEE standards symbol number.

A simple example

Read the operating mechanism and the contact reference state together. Cross-reference every associated contact to the same device and show which movement, signal or reset changes its condition; the symbol alone does not establish the complete switching sequence.

Identify the device and formRead the connections and stateCheck the equipment reference
A guide to reading this reference. The original symbol illustration and its drawing notes appear below; these boxes are not a wiring diagram.

What the drawings help you do

Show the reference terminal and each selectable measurement path. The position table should make clear which reading the operator receives at each position. Show the neutral/reference connection and each selected phase in the position table. Phase-to-neutral and phase-to-phase measurements have different connection paths. The linked functional counterpart explains the same operating role in its own drawing context; agreement of every detailed convention mark is not asserted.

This particular reference

IEEE-library form of phase-to-neutral voltmeter selector: this representation identifies selection among phase-to-neutral voltage measurement connections. Phase-to-neutral and phase-to-phase measurements have different connection paths.

Normally open / normally closed
The contact state in the normal condition defined for the drawing.
Phase
One of the related AC waveforms in a power system.
Terminal
An identified point where a conductor connects.

Read the source: Autodesk IEEE Symbol Preview — Miscellaneous Switches

IEEE / ANSI · 3 Voltage Phase-to-Neutral Switch

Autodesk IEEE Symbol Preview: Miscellaneous Switches, block HSW1S91. Matching functional counterpart linked separately. Independently drawn educational geometry; not a certified IEEE glyph or database identifier.

Shown as an independently authored educational illustration. Use the cited publication and drawing legend to verify the required drafting form.

Schematic · HSW1S91ANSI/IEEE Phase-to-neutral voltmeter selector form: original educational illustration
Original educational illustrationNot to scale · See source and graphic notes

What it represents

This reference locates phase-to-neutral voltmeter selector in Autodesk's IEEE-oriented miscellaneous switches family. This representation identifies selection among phase-to-neutral voltage measurement connections. The meter is connected to the selected phase relative to the documented neutral or reference point. That connection differs from measuring between two phase conductors. The public library uses HSW1S91 for its horizontal representation; this is a vendor block name, not an IEEE standards symbol number.

Read the operating mechanism and the contact reference state together. Cross-reference every associated contact to the same device and show which movement, signal or reset changes its condition; the symbol alone does not establish the complete switching sequence.

Show the reference terminal and each selectable measurement path. The position table should make clear which reading the operator receives at each position. Show the neutral/reference connection and each selected phase in the position table. Phase-to-neutral and phase-to-phase measurements have different connection paths. The linked functional counterpart explains the same operating role in its own drawing context; agreement of every detailed convention mark is not asserted.

How to read it

  • Show the neutral/reference connection and each selected phase in the position table.
  • Phase-to-neutral and phase-to-phase measurements have different connection paths.

Information to show or reference

  • Identify the associated device, circuit or diagram boundary.
  • Show the neutral/reference connection and each selected phase in the position table.
  • Cross-reference the equipment data, terminal mapping or operating-state legend needed to interpret the form.

A distinction that matters

Phase-to-neutral and phase-to-phase measurements have different connection paths.

Sources you can follow

These public references support the explanation and provide further detail. Their graphics and downloadable files remain with their publishers.

Autodesk IEEE Symbol Preview — Miscellaneous Switches

Public IEEE-oriented Miscellaneous Switches table explicitly lists HSW1S91 as 3 Voltage Phase-to-Neutral Switch. This supports the vendor convention context, not reproduction of the publisher graphic.

Autodesk · Public reference checked 14 October 2026 · Link only

About this graphic

This illustration was authored independently by Elora Grid to explain the concept. It is not reproduced from a customer drawing, an official standard graphic or a manufacturer CAD file. Its correspondence to an exact IEC or IEEE symbol identifier has not been certified.

SVG and DXF downloads contain this original artwork. DXF uses unscaled drawing units; a GA envelope supplies no product dimensions, clearances or fabrication information. Original artwork is available under CC BY 4.0. Third-party references retain their own terms.

Entry JSON · Entry Markdown · Last editorial update: 28 October 2026

Put the reference into a drawing workflow.

Elora Grid helps electrical teams work with drawings, specifications and equipment information. Explore the drafting workflow or join the early-access waitlist.

Explore drafting