IEC · SS

IEC selector-switch contact: 2 position normally open return from right

Selector-switch contact form: 2 Position Normally Open Return From Right.

In plain English

What does IEC selector-switch contact: 2 position normally open return from right mean?

A rotary selector has discrete handle positions and one or more contact blocks driven by its mechanism. A contact shown as normally open or normally closed describes the stated reference position; it does not give the whole switching table across the remaining positions. This entry identifies the 2 position normally open return from right form in the publisher's IEC-context family.

A simple example

For a local/off/remote selector, prepare a contact-versus-position chart alongside the schematic. The chart tells the installer which input is active at each handle setting, while spring-return, maintained and key-operated marks explain how the operator reaches or leaves that setting. The normally-open designation starts with a non-conducting output or open contact in the documented reference condition; operation changes that state. The return arrow applies to the right operating position. Other positions need their own return or maintained-state description.

Identify the device and formRead the connections and stateCheck the equipment reference
A guide to reading this reference. The original symbol illustration and its drawing notes appear below; these boxes are not a wiring diagram.

What the drawings help you do

A vendor neutral-position number must be read with that vendor form and the project legend. It does not automatically establish a key-removal position, a contact overlap or an off state. Those details need their own table or equipment reference.

This particular reference

Selector-switch contact form: 2 Position Normally Open Return From Right. This entry adds the 2 position normally open return from right detail to the broader selector-switch contact family. A vendor neutral-position number must be read with that vendor form and the project legend. It does not automatically establish a key-removal position, a contact overlap or an off state. Those details need their own table or equipment reference.

Normally open / normally closed
The contact state in the normal condition defined for the drawing.
Signal
Electrical information passed between devices, rather than necessarily the main power supply.
Rating
A value stating the conditions for which equipment is specified.

Read the source: Selector-switch contact and operating variants

IEC · 2 Position Normally Open Return From Right

Autodesk IEC-60617 Symbol Preview: Selector Switches, HSS112R / VSS112R. This identifies the publisher's library context; exact IEC graphics and database identities are not asserted.

Shown as an independently authored educational illustration. Use the cited publication and drawing legend to verify the required drafting form.

Schematic · SSIEC selector-switch contact: 2 position normally open return from right: original educational illustration
Original educational illustrationNot to scale · See source and graphic notes

What it represents

A rotary selector has discrete handle positions and one or more contact blocks driven by its mechanism. A contact shown as normally open or normally closed describes the stated reference position; it does not give the whole switching table across the remaining positions. This entry identifies the 2 position normally open return from right form in the publisher's IEC-context family.

For a local/off/remote selector, prepare a contact-versus-position chart alongside the schematic. The chart tells the installer which input is active at each handle setting, while spring-return, maintained and key-operated marks explain how the operator reaches or leaves that setting. The normally-open designation starts with a non-conducting output or open contact in the documented reference condition; operation changes that state. The return arrow applies to the right operating position. Other positions need their own return or maintained-state description.

A vendor neutral-position number must be read with that vendor form and the project legend. It does not automatically establish a key-removal position, a contact overlap or an off state. Those details need their own table or equipment reference.

How to read it

  • The normally-open designation starts with a non-conducting output or open contact in the documented reference condition; operation changes that state.
  • The return arrow applies to the right operating position. Other positions need their own return or maintained-state description.
  • A vendor neutral-position number must be read with that vendor form and the project legend. It does not automatically establish a key-removal position, a contact overlap or an off state. Those details need their own table or equipment reference.

Information to show or reference

  • Label every handle position and preserve its reference orientation.
  • Cross-reference a contact-versus-position chart.
  • State maintained positions, return directions and any key-removal conditions.

A distinction that matters

This entry adds the 2 position normally open return from right detail to the broader selector-switch contact family. A vendor neutral-position number must be read with that vendor form and the project legend. It does not automatically establish a key-removal position, a contact overlap or an off state. Those details need their own table or equipment reference.

Sources you can follow

These public references support the explanation and provide further detail. Their graphics and downloadable files remain with their publishers.

Selector-switch contact and operating variants

Public Selector Switches table explicitly lists HSS112R / VSS112R with this operating or connection form. Vendor graphics are linked, not copied.

Autodesk · Public reference checked 13 October 2026 · Link only

About this graphic

This illustration was authored independently by Elora Grid to explain the concept. It is not reproduced from a customer drawing, an official standard graphic or a manufacturer CAD file. Its correspondence to an exact IEC or IEEE symbol identifier has not been certified.

SVG and DXF downloads contain this original artwork. DXF uses unscaled drawing units; a GA envelope supplies no product dimensions, clearances or fabrication information. Original artwork is available under CC BY 4.0. Third-party references retain their own terms.

Entry JSON · Entry Markdown · Last editorial update: 28 October 2026

Put the reference into a drawing workflow.

Elora Grid helps electrical teams work with drawings, specifications and equipment information. Explore the drafting workflow or join the early-access waitlist.

Explore drafting