Selector switch
An operator switch selecting between documented control positions.
Selector-switch contact form: 3 Stable Position Normally Open Key Operated Neutral 2.
In plain English
A rotary selector has discrete handle positions and one or more contact blocks driven by its mechanism. A contact shown as normally open or normally closed describes the stated reference position; it does not give the whole switching table across the remaining positions. This entry identifies the 3 stable position normally open key operated neutral 2 form in the publisher's IEC-context family.
For a local/off/remote selector, prepare a contact-versus-position chart alongside the schematic. The chart tells the installer which input is active at each handle setting, while spring-return, maintained and key-operated marks explain how the operator reaches or leaves that setting. The normally-open designation starts with a non-conducting output or open contact in the documented reference condition; operation changes that state. Keep the publisher's neutral 2 designation beside its contact table; do not infer the complete position sequence from that number.
A vendor neutral-position number must be read with that vendor form and the project legend. It does not automatically establish a key-removal position, a contact overlap or an off state. Those details need their own table or equipment reference.
Selector-switch contact form: 3 Stable Position Normally Open Key Operated Neutral 2. This entry adds the 3 stable position normally open key operated neutral 2 detail to the broader selector-switch contact family. A vendor neutral-position number must be read with that vendor form and the project legend. It does not automatically establish a key-removal position, a contact overlap or an off state. Those details need their own table or equipment reference.
Read the source: AutoCAD Electrical: Three-position selectors
Autodesk IEC-60617 Symbol Preview: 3 Position Selector Switches, HSS11S45 / VSS11S45. This identifies the publisher's library context; exact IEC graphics and database identities are not asserted.
Shown as an independently authored educational illustration. Use the cited publication and drawing legend to verify the required drafting form.
A rotary selector has discrete handle positions and one or more contact blocks driven by its mechanism. A contact shown as normally open or normally closed describes the stated reference position; it does not give the whole switching table across the remaining positions. This entry identifies the 3 stable position normally open key operated neutral 2 form in the publisher's IEC-context family.
For a local/off/remote selector, prepare a contact-versus-position chart alongside the schematic. The chart tells the installer which input is active at each handle setting, while spring-return, maintained and key-operated marks explain how the operator reaches or leaves that setting. The normally-open designation starts with a non-conducting output or open contact in the documented reference condition; operation changes that state. Keep the publisher's neutral 2 designation beside its contact table; do not infer the complete position sequence from that number.
A vendor neutral-position number must be read with that vendor form and the project legend. It does not automatically establish a key-removal position, a contact overlap or an off state. Those details need their own table or equipment reference.
This entry adds the 3 stable position normally open key operated neutral 2 detail to the broader selector-switch contact family. A vendor neutral-position number must be read with that vendor form and the project legend. It does not automatically establish a key-removal position, a contact overlap or an off state. Those details need their own table or equipment reference.
These public references support the explanation and provide further detail. Their graphics and downloadable files remain with their publishers.
Public 3 Position Selector Switches table explicitly lists HSS11S45 / VSS11S45 with this operating or connection form. Vendor graphics are linked, not copied.
This illustration was authored independently by Elora Grid to explain the concept. It is not reproduced from a customer drawing, an official standard graphic or a manufacturer CAD file. Its correspondence to an exact IEC or IEEE symbol identifier has not been certified.
SVG and DXF downloads contain this original artwork. DXF uses unscaled drawing units; a GA envelope supplies no product dimensions, clearances or fabrication information. Original artwork is available under CC BY 4.0. Third-party references retain their own terms.
Elora Grid helps electrical teams work with drawings, specifications and equipment information. Explore the drafting workflow or join the early-access waitlist.