Luminaire general plan symbol
General installation plan symbol for a luminaire or lighting point, drawn as a crossed circle at the ceiling position.
Plan mark for a wall-mounted luminaire, drawn as a luminaire symbol attached to the wall line.
In plain English
Wall lights are drawn with the luminaire mark touching or attached to the wall by a short bar, which distinguishes them from ceiling luminaires. The mounting height is either noted on the symbol or covered by a typical detail.
Wall luminaires are used in corridors, stairwells, bedrooms and external facades. The installer needs the mounting height and the fitting type to set the box before plastering, so this symbol usually carries a height tag. The symbol does not indicate the light distribution (uplight, downlight or both). That comes from the schedule.
Note the wall attachment bar. Read the mounting height tag. A ceiling luminaire stands free in the room on plan; the wall form is attached to the wall line.
Plan mark for a wall-mounted luminaire, drawn as a luminaire symbol attached to the wall line. A ceiling luminaire stands free in the room on plan; the wall form is attached to the wall line.
Read the source: IEC graphical symbols for diagrams · Electrical installation design methodology and references
IEC 60617 installation-plan style (architectural and topographical installation symbols); independently drawn, not certified IEC geometry or a database identifier.
Shown as an independently authored educational illustration. Use the cited publication and drawing legend to verify the required drafting form.
Wall lights are drawn with the luminaire mark touching or attached to the wall by a short bar, which distinguishes them from ceiling luminaires. The mounting height is either noted on the symbol or covered by a typical detail.
Wall luminaires are used in corridors, stairwells, bedrooms and external facades. The installer needs the mounting height and the fitting type to set the box before plastering, so this symbol usually carries a height tag. The symbol does not indicate the light distribution (uplight, downlight or both). That comes from the schedule.
A ceiling luminaire stands free in the room on plan; the wall form is attached to the wall line.
These public references support the explanation and provide further detail. Their graphics and downloadable files remain with their publishers.
IEC graphical symbol context for installation plans; independently drawn here.
Installation design methodology covering lighting circuits and final distribution.
This illustration was authored independently by Elora Grid to explain the concept. It is not reproduced from a customer drawing, an official standard graphic or a manufacturer CAD file. Its correspondence to an exact IEC or IEEE symbol identifier has not been certified.
SVG and DXF downloads contain this original artwork. DXF uses unscaled drawing units; a GA envelope supplies no product dimensions, clearances or fabrication information. Original artwork is available under CC BY 4.0. Third-party references retain their own terms.