Manual call point plan symbol
Fire alarm plan symbol for a manual call point that occupants operate to raise the alarm, placed at exits.
US-style plan symbol for a manual fire alarm pull station, commonly a square with an F, at each exit.
In plain English
US plans mark manual pull stations with a square containing F or a pull-station shape, located within reach of each exit door. Single-action and double-action types are distinguished in the device schedule.
The plan is used to check that pull stations are within the required distance of each exit and at the required height. Protective covers may be specified where malicious activation is a risk. The symbol does not show the action type or cover.
Check location near each exit. Check covers where specified. The IEC manual call point is a break-glass or resettable push; the US pull station is operated by pulling a handle.
US-style plan symbol for a manual fire alarm pull station, commonly a square with an F, at each exit. The IEC manual call point is a break-glass or resettable push; the US pull station is operated by pulling a handle.
Read the source: IEEE/ANSI 315-1975: graphic symbols for electrical and electronics diagrams
US architectural electrical plan practice in the ANSI Y32.9 lineage, read alongside IEEE 315 context; independently drawn, not a certified IEEE or ANSI graphic.
Shown as an independently authored educational illustration. Use the cited publication and drawing legend to verify the required drafting form.
US plans mark manual pull stations with a square containing F or a pull-station shape, located within reach of each exit door. Single-action and double-action types are distinguished in the device schedule.
The plan is used to check that pull stations are within the required distance of each exit and at the required height. Protective covers may be specified where malicious activation is a risk. The symbol does not show the action type or cover.
The IEC manual call point is a break-glass or resettable push; the US pull station is operated by pulling a handle.
These public references support the explanation and provide further detail. Their graphics and downloadable files remain with their publishers.
Graphic-symbol standards context and official status; not a source of reproduced artwork.
This illustration was authored independently by Elora Grid to explain the concept. It is not reproduced from a customer drawing, an official standard graphic or a manufacturer CAD file. Its correspondence to an exact IEC or IEEE symbol identifier has not been certified.
SVG and DXF downloads contain this original artwork. DXF uses unscaled drawing units; a GA envelope supplies no product dimensions, clearances or fabrication information. Original artwork is available under CC BY 4.0. Third-party references retain their own terms.
Elora Grid helps electrical teams work with drawings, specifications and equipment information. Explore the drafting workflow or join the early-access waitlist.