Fire alarm sounder plan symbol
Plan symbol for a fire alarm sounder that gives the audible evacuation signal.
Fire alarm plan symbol for a manual call point that occupants operate to raise the alarm, placed at exits.
In plain English
Manual call points, often break-glass or resettable push units, are drawn as a square with a filled or crossed inner square, or a circle with a dot, at their wall position. They are placed at storey exits and exits to open air so a person leaving can raise the alarm.
Mounting height and travel distance to the nearest call point are set by the fire code. The plan allows inspectors to check these quickly.
The symbol does not show whether the unit is resettable or break-glass, or whether it has a protective cover. The schedule states this.
Fire alarm plan symbol for a manual call point that occupants operate to raise the alarm, placed at exits. A bell push or assistance call button looks similar on a plan; the call point belongs to the fire alarm system.
Read the source: IEC graphical symbols for diagrams · Electrical installation design methodology and references
IEC 60617 installation-plan style (architectural and topographical installation symbols); independently drawn, not certified IEC geometry or a database identifier.
Shown as an independently authored educational illustration. Use the cited publication and drawing legend to verify the required drafting form.
Manual call points, often break-glass or resettable push units, are drawn as a square with a filled or crossed inner square, or a circle with a dot, at their wall position. They are placed at storey exits and exits to open air so a person leaving can raise the alarm.
Mounting height and travel distance to the nearest call point are set by the fire code. The plan allows inspectors to check these quickly.
The symbol does not show whether the unit is resettable or break-glass, or whether it has a protective cover. The schedule states this.
A bell push or assistance call button looks similar on a plan; the call point belongs to the fire alarm system.
These public references support the explanation and provide further detail. Their graphics and downloadable files remain with their publishers.
IEC graphical symbol context for installation plans; independently drawn here.
Installation design context: life-safety systems are coordinated with the building electrical design.
This illustration was authored independently by Elora Grid to explain the concept. It is not reproduced from a customer drawing, an official standard graphic or a manufacturer CAD file. Its correspondence to an exact IEC or IEEE symbol identifier has not been certified.
SVG and DXF downloads contain this original artwork. DXF uses unscaled drawing units; a GA envelope supplies no product dimensions, clearances or fabrication information. Original artwork is available under CC BY 4.0. Third-party references retain their own terms.
Elora Grid helps electrical teams work with drawings, specifications and equipment information. Explore the drafting workflow or join the early-access waitlist.