Firefighter telephone outlet plan symbol

Plan symbol for a firefighter or emergency warden telephone outlet used for communication during an incident.

In plain English

What does Firefighter telephone outlet plan mean?

Firefighter telephone outlets, or warden intercommunication points, give two-way voice communication between floors and the fire control point. Plans draw a telephone handset mark or outlet tagged FFT, EWIS or WIP at stair landings and plant rooms.

A simple example

The circuits are monitored and often fire-rated, so the plan symbol tells the installer to use the specified fire-resistant cable. Positions follow the fire code and brigade requirements. The symbol does not show whether the outlet is a jack for a portable handset or a fixed phone.

Identify the device and formRead the connections and stateCheck the equipment reference
A guide to reading this reference. The original symbol illustration and its drawing notes appear below; these boxes are not a wiring diagram.

What the drawings help you do

Check positions at stair landings. Check fire-rated cable requirements. A general telephone outlet belongs to the communications network; this is a life-safety communication point.

This particular reference

Plan symbol for a firefighter or emergency warden telephone outlet used for communication during an incident. A general telephone outlet belongs to the communications network; this is a life-safety communication point.

Rating
A value stating the conditions for which equipment is specified.
Schematic
A drawing showing function and connections rather than physical appearance.

Read the source: IEC graphical symbols for diagrams · Electrical installation design methodology and references

IEC · Fire telephone outlet

IEC 60617 installation-plan style (architectural and topographical installation symbols); independently drawn, not certified IEC geometry or a database identifier.

Shown as an independently authored educational illustration. Use the cited publication and drawing legend to verify the required drafting form.

GA · FFTFirefighter telephone outlet plan symbol: original educational illustration
Original educational illustrationNot to scale · See source and graphic notes

What it represents

Firefighter telephone outlets, or warden intercommunication points, give two-way voice communication between floors and the fire control point. Plans draw a telephone handset mark or outlet tagged FFT, EWIS or WIP at stair landings and plant rooms.

The circuits are monitored and often fire-rated, so the plan symbol tells the installer to use the specified fire-resistant cable. Positions follow the fire code and brigade requirements. The symbol does not show whether the outlet is a jack for a portable handset or a fixed phone.

How to read it

  • Check positions at stair landings.
  • Check fire-rated cable requirements.

Information to show or reference

  • State jack or fixed handset.
  • Specify fire-rated cabling.
  • Link to master station.

A distinction that matters

A general telephone outlet belongs to the communications network; this is a life-safety communication point.

Sources you can follow

These public references support the explanation and provide further detail. Their graphics and downloadable files remain with their publishers.

IEC graphical symbols for diagrams

IEC graphical symbol context for installation plans; independently drawn here.

IEC · Public reference checked 13 October 2026 · Link only

Electrical installation design methodology and references

Installation design context: life-safety systems are coordinated with the building electrical design.

Schneider Electric — Electrical Installation Guide · Public reference checked 13 October 2026 · Link only

About this graphic

This illustration was authored independently by Elora Grid to explain the concept. It is not reproduced from a customer drawing, an official standard graphic or a manufacturer CAD file. Its correspondence to an exact IEC or IEEE symbol identifier has not been certified.

SVG and DXF downloads contain this original artwork. DXF uses unscaled drawing units; a GA envelope supplies no product dimensions, clearances or fabrication information. Original artwork is available under CC BY 4.0. Third-party references retain their own terms.

Entry JSON · Entry Markdown · Last editorial update: 28 October 2026

Put the reference into a drawing workflow.

Elora Grid helps electrical teams work with drawings, specifications and equipment information. Explore the drafting workflow or join the early-access waitlist.

Explore drafting