Socket outlet with protective earth contact
Installation plan mark for a socket outlet that includes a protective earth contact for Class I appliances.
Plan mark for a socket outlet fed through a safety isolating transformer, typically a bathroom shaver point.
In plain English
A shaver supply unit contains a small isolating transformer so that the outlet is not referenced to earth. IEC-style plan symbols show the outlet half circle with two linked circles on the lead, the same pair of circles used for a transformer in diagrams, to show that the outlet is fed through isolation.
This is the only general outlet permitted in some bathroom zones, so the symbol tells the installer which accessory to buy and tells the inspector why an outlet appears close to a basin. The low power rating means it is for shavers and toothbrushes, not hair dryers or heaters.
The symbol does not show the transformer rating or the dual-voltage selector that many units include. A plain outlet drawn in a bathroom is not the same and may breach zone requirements.
Plan mark for a socket outlet fed through a safety isolating transformer, typically a bathroom shaver point. A general outlet in a bathroom position is not isolated from earth; the shaver supply unit is.
Read the source: IEC graphical symbols for diagrams · Electrical installation design methodology and references
IEC 60617 installation-plan style (architectural and topographical installation symbols); independently drawn, not certified IEC geometry or a database identifier.
Shown as an independently authored educational illustration. Use the cited publication and drawing legend to verify the required drafting form.
A shaver supply unit contains a small isolating transformer so that the outlet is not referenced to earth. IEC-style plan symbols show the outlet half circle with two linked circles on the lead, the same pair of circles used for a transformer in diagrams, to show that the outlet is fed through isolation.
This is the only general outlet permitted in some bathroom zones, so the symbol tells the installer which accessory to buy and tells the inspector why an outlet appears close to a basin. The low power rating means it is for shavers and toothbrushes, not hair dryers or heaters.
The symbol does not show the transformer rating or the dual-voltage selector that many units include. A plain outlet drawn in a bathroom is not the same and may breach zone requirements.
A general outlet in a bathroom position is not isolated from earth; the shaver supply unit is.
These public references support the explanation and provide further detail. Their graphics and downloadable files remain with their publishers.
IEC committee context for graphical symbols used in diagrams and installation documents; not a source of reproduced artwork.
Installation design methodology context: circuits, outlets and final distribution are planned before symbols are placed.
This illustration was authored independently by Elora Grid to explain the concept. It is not reproduced from a customer drawing, an official standard graphic or a manufacturer CAD file. Its correspondence to an exact IEC or IEEE symbol identifier has not been certified.
SVG and DXF downloads contain this original artwork. DXF uses unscaled drawing units; a GA envelope supplies no product dimensions, clearances or fabrication information. Original artwork is available under CC BY 4.0. Third-party references retain their own terms.
Elora Grid helps electrical teams work with drawings, specifications and equipment information. Explore the drafting workflow or join the early-access waitlist.