IEC three-state output qualifier
Downward triangle inside an outline marking an output that can enter a high-impedance state.
Input labelled EN that enables all outputs of the element when at its internal 1 state.
In plain English
An input labelled EN inside the outline enables every external output of the element. At its internal 0 state, open-circuit outputs are off, three-state outputs go to high impedance and other outputs take their internal 0 state. It has no effect on inputs, according to TI's public summary of the notation.
When an enable affects only some outputs, the notation changes to EN dependency with a number, for example EN1 with affected outputs labelled 1. Readers should distinguish a plain EN from ENm because the scope is different.
The label does not show the timing needed between enable and valid output. Enable and disable times are device data. Check the enabled and disabled output conditions in the selected device truth table before connecting a shared bus.
Input labelled EN that enables all outputs of the element when at its internal 1 state. A C (control) input permits action of affected inputs; EN acts on outputs.
Read the source: Overview of IEEE Standard 91-1984: explanation of logic symbols (SDYZ001A)
Qualifying-symbol and dependency conventions as explained in TI's public overview of IEEE Std 91-1984, which incorporates IEC 617-12 work. Independent educational drawing; not certified IEC geometry or an IEC database identifier.
Shown as an independently authored educational illustration. Use the cited publication and drawing legend to verify the required drafting form.
An input labelled EN inside the outline enables every external output of the element. At its internal 0 state, open-circuit outputs are off, three-state outputs go to high impedance and other outputs take their internal 0 state. It has no effect on inputs, according to TI's public summary of the notation.
When an enable affects only some outputs, the notation changes to EN dependency with a number, for example EN1 with affected outputs labelled 1. Readers should distinguish a plain EN from ENm because the scope is different.
The label does not show the timing needed between enable and valid output. Enable and disable times are device data. Check the enabled and disabled output conditions in the selected device truth table before connecting a shared bus.
A C (control) input permits action of affected inputs; EN acts on outputs.
These public references support the explanation and provide further detail. Their graphics and downloadable files remain with their publishers.
Describes the EN input and its effect on different output types.
This illustration was authored independently by Elora Grid to explain the concept. It is not reproduced from a customer drawing, an official standard graphic or a manufacturer CAD file. Its correspondence to an exact IEC or IEEE symbol identifier has not been certified.
SVG and DXF downloads contain this original artwork. DXF uses unscaled drawing units; a GA envelope supplies no product dimensions, clearances or fabrication information. Original artwork is available under CC BY 4.0. Third-party references retain their own terms.
Elora Grid helps electrical teams work with drawings, specifications and equipment information. Explore the drafting workflow or join the early-access waitlist.