IEC arithmetic logic unit (ALU)
IEC element marked ALU, performing arithmetic or logic functions on two words as chosen by mode inputs.
IEC element marked CPG that computes carries for several adder stages at once to speed up arithmetic.
In plain English
The CPG additional drawing mark identifies a look-ahead carry generator. It takes carry generate and carry propagate signals from several adder or ALU stages and produces their carry inputs in parallel, avoiding the delay of a rippling carry chain.
On block diagrams of arithmetic sections the CPG sits beside a row of ALUs, with generate and propagate lines going in and carry lines coming out. Recognising it explains why carries do not pass directly from one ALU to the next.
The symbol does not indicate how many stages it serves; count the input groups or refer to the device data. Label the carry input and output ordering explicitly so the arithmetic stages cannot be connected in the wrong significance order.
IEC element marked CPG that computes carries for several adder stages at once to speed up arithmetic. A ripple-carry arrangement chains CO to CI directly with no CPG element.
Read the source: Overview of IEEE Standard 91-1984: explanation of logic symbols (SDYZ001A)
Qualifying-symbol and dependency conventions as explained in TI's public overview of IEEE Std 91-1984, which incorporates IEC 617-12 work. Independent educational drawing; not certified IEC geometry or an IEC database identifier.
Shown as an independently authored educational illustration. Use the cited publication and drawing legend to verify the required drafting form.
The CPG qualifier identifies a look-ahead carry generator. It takes carry generate and carry propagate signals from several adder or ALU stages and produces their carry inputs in parallel, avoiding the delay of a rippling carry chain.
On block diagrams of arithmetic sections the CPG sits beside a row of ALUs, with generate and propagate lines going in and carry lines coming out. Recognising it explains why carries do not pass directly from one ALU to the next.
The symbol does not indicate how many stages it serves; count the input groups or refer to the device data. Label the carry input and output ordering explicitly so the arithmetic stages cannot be connected in the wrong significance order.
A ripple-carry arrangement chains CO to CI directly with no CPG element.
These public references support the explanation and provide further detail. Their graphics and downloadable files remain with their publishers.
Lists CPG as the look-ahead carry generator qualifier.
This illustration was authored independently by Elora Grid to explain the concept. It is not reproduced from a customer drawing, an official standard graphic or a manufacturer CAD file. Its correspondence to an exact IEC or IEEE symbol identifier has not been certified.
SVG and DXF downloads contain this original artwork. DXF uses unscaled drawing units; a GA envelope supplies no product dimensions, clearances or fabrication information. Original artwork is available under CC BY 4.0. Third-party references retain their own terms.
Elora Grid helps electrical teams work with drawings, specifications and equipment information. Explore the drafting workflow or join the early-access waitlist.