Retriggerable monostable
Produces a timed output pulse that can be extended by a qualifying retrigger condition.
IEC monostable showing only the single-pulse qualifier; each new trigger restarts the output pulse.
In plain English
The retriggerable monostable is marked with the single pulse shape without the preceding 1. Each trigger during the output pulse restarts the timing, so the output remains active as long as triggers arrive more often than the set period.
This behaviour is useful for missing-pulse detection and activity monitoring, where the output drops only when a regular signal stops. The drawing should note the expected trigger rate and the timeout chosen.
The symbol does not show whether a clear input truncates the pulse. Check for an R input and its polarity. Include reset behaviour in the timing chart so a missing-pulse indication can be distinguished from an externally forced clear.
IEC monostable showing only the single-pulse additional drawing mark; each new trigger restarts the output pulse. The non-retriggerable form has the 1 additional drawing mark and ignores triggers during the pulse.
Read the source: Overview of IEEE Standard 91-1984: explanation of logic symbols (SDYZ001A) · CD74HC123 — retriggerable monostables
Qualifying-symbol and dependency conventions as explained in TI's public overview of IEEE Std 91-1984, which incorporates IEC 617-12 work. Independent educational drawing; not certified IEC geometry or an IEC database identifier. The counterpart is the matching functional concept; no equivalence of every detailed standard graphic is asserted.
Shown as an independently authored educational illustration. Use the cited publication and drawing legend to verify the required drafting form.
The retriggerable monostable is marked with the single pulse shape without the preceding 1. Each trigger during the output pulse restarts the timing, so the output remains active as long as triggers arrive more often than the set period.
This behaviour is useful for missing-pulse detection and activity monitoring, where the output drops only when a regular signal stops. The drawing should note the expected trigger rate and the timeout chosen.
The symbol does not show whether a clear input truncates the pulse. Check for an R input and its polarity. Include reset behaviour in the timing chart so a missing-pulse indication can be distinguished from an externally forced clear.
The non-retriggerable form has the 1 qualifier and ignores triggers during the pulse.
These public references support the explanation and provide further detail. Their graphics and downloadable files remain with their publishers.
Lists the retriggerable monostable general qualifier.
Retriggerable monostable device documentation.
This illustration was authored independently by Elora Grid to explain the concept. It is not reproduced from a customer drawing, an official standard graphic or a manufacturer CAD file. Its correspondence to an exact IEC or IEEE symbol identifier has not been certified.
SVG and DXF downloads contain this original artwork. DXF uses unscaled drawing units; a GA envelope supplies no product dimensions, clearances or fabrication information. Original artwork is available under CC BY 4.0. Third-party references retain their own terms.
Elora Grid helps electrical teams work with drawings, specifications and equipment information. Explore the drafting workflow or join the early-access waitlist.