Protection functions · 50G

Instantaneous ground overcurrent

Supervises the ground-current input or ground-fault quantity identified by the selected relay.

SLD / Schematic · 50GInstantaneous ground overcurrent: original educational illustration
Original educational illustrationNot to scale · See source and graphic notes

What it represents

Supervises the ground-current input or ground-fault quantity identified by the selected relay.

The drafting record should connect this function to the ground CT input, earthing connection and sensor polarity, then trace the ground overcurrent trip and circuit earthing reference. Keep the complete designation and equipment tag together so that the SLD, relay logic and terminal schedule describe the same implementation.

The cited mapping is a public manufacturer example (SEL generator protection feature table). Suffixes are not universal equivalences across products, and this reference supplies neither a protection setting nor certification of the selected scheme.

How to read it

  • Identify the ground CT input, earthing connection and sensor polarity.
  • Trace the ground overcurrent trip and circuit earthing reference.

Information to show or reference

  • Label the ground CT input, earthing connection and sensor polarity.
  • Cross-reference the ground overcurrent trip and circuit earthing reference.
  • Retain the complete suffix, selected device tag and manufacturer manual revision.

A distinction that matters

G is application-dependent: in 50G it denotes ground current, while 87G commonly denotes generator differential.

Sources you can follow

These public references support the explanation and provide further detail. Their graphics and downloadable files remain with their publishers.

Generator protection feature and function comparison

Public primary-source function or application mapping used to identify this designation; wording and drafting notes are original.

Schweitzer Engineering Laboratories · Public reference checked 13 October 2026 · Link only

IEEE C37.2-2022: power-system device function numbers

Device-number and suffix convention. This page is not a reproduction of the full licensed standard.

IEEE · Public reference checked 13 October 2026 · Link only

About this graphic

This illustration was authored independently by Elora Grid to explain the concept. It is not reproduced from a customer drawing, an official standard graphic or a manufacturer CAD file. Its correspondence to an exact IEC or IEEE symbol identifier has not been certified.

SVG and DXF downloads contain this original artwork. DXF uses unscaled drawing units; a GA envelope supplies no product dimensions, clearances or fabrication information. Original artwork is available under CC BY 4.0. Third-party references retain their own terms.

Entry JSON · Entry Markdown · Last editorial update: 13 October 2026