Protection functions · 67X

Measured ground directional overcurrent

Applies directional supervision to the separately measured ground or neutral current element in the cited Eaton family.

SLD / Schematic · 67XMeasured ground directional overcurrent: original educational illustration
Original educational illustrationNot to scale · See source and graphic notes

What it represents

Applies directional supervision to the separately measured ground or neutral current element in the cited Eaton family.

The drafting record should connect this function to the dedicated ground/neutral CT input and polarising references, then trace the measured directional earth-fault trip. Keep the complete designation and equipment tag together so that the SLD, relay logic and terminal schedule describe the same implementation.

The cited mapping is a public manufacturer example (Eaton EGR family). Suffixes are not universal equivalences across products, and this reference supplies neither a protection setting nor certification of the selected scheme.

How to read it

  • Identify the dedicated ground/neutral CT input and polarising references.
  • Trace the measured directional earth-fault trip.

Information to show or reference

  • Label the dedicated ground/neutral CT input and polarising references.
  • Cross-reference the measured directional earth-fault trip.
  • Retain the complete suffix, selected device tag and manufacturer manual revision.

A distinction that matters

The X suffix has a product-specific measured-input meaning here; retain the relay manual reference rather than assuming a universal suffix rule.

Sources you can follow

These public references support the explanation and provide further detail. Their graphics and downloadable files remain with their publishers.

EGR-5000 generator protection: public function overview

Public primary-source function or application mapping used to identify this designation; wording and drafting notes are original.

Eaton · Public reference checked 13 October 2026 · Link only

IEEE C37.2-2022: power-system device function numbers

Device-number and suffix convention. This page is not a reproduction of the full licensed standard.

IEEE · Public reference checked 13 October 2026 · Link only

About this graphic

This illustration was authored independently by Elora Grid to explain the concept. It is not reproduced from a customer drawing, an official standard graphic or a manufacturer CAD file. Its correspondence to an exact IEC or IEEE symbol identifier has not been certified.

SVG and DXF downloads contain this original artwork. DXF uses unscaled drawing units; a GA envelope supplies no product dimensions, clearances or fabrication information. Original artwork is available under CC BY 4.0. Third-party references retain their own terms.

Entry JSON · Entry Markdown · Last editorial update: 13 October 2026

Put the reference into a drawing workflow.

Elora Grid helps electrical teams work with drawings, specifications and equipment information. Explore the drafting workflow or join the early-access waitlist.

Explore drafting