Protection functions · 8

Control power disconnecting device

Isolates the supply feeding a control circuit or control-power bus.

SLD / Schematic · 8Control power disconnecting device: original educational illustration
Original educational illustrationNot to scale · See source and graphic notes

What it represents

Isolates the supply feeding a control circuit or control-power bus.

In a drafting package, connect this reference to the control supply source and disconnect poles. The associated drawing should trace the downstream control circuits and auxiliary contacts; the number identifies the role and does not specify the terminal arrangement, ratings or operating settings.

How to read it

  • Identify the control supply source and disconnect poles.
  • Trace the downstream control circuits and auxiliary contacts.

Information to show or reference

  • Label the control supply source and disconnect poles.
  • Cross-reference the downstream control circuits and auxiliary contacts.
  • Identify the device tag, manual revision and logic drawing that define this implementation.

A distinction that matters

Control-power isolation does not by itself isolate the associated primary power circuit.

Sources you can follow

These public references support the explanation and provide further detail. Their graphics and downloadable files remain with their publishers.

ANSI device-number and suffix reference table

Public manufacturer number/name association. Drafting explanations are independently written.

Schweitzer Engineering Laboratories · Public reference checked 13 October 2026 · Link only

IEEE C37.2-2022: power-system device function numbers

Normative device-number publication; exact edition wording and compliance require the licensed standard.

IEEE · Public reference checked 13 October 2026 · Link only

About this graphic

This illustration was authored independently by Elora Grid to explain the concept. It is not reproduced from a customer drawing, an official standard graphic or a manufacturer CAD file. Its correspondence to an exact IEC or IEEE symbol identifier has not been certified.

SVG and DXF downloads contain this original artwork. DXF uses unscaled drawing units; a GA envelope supplies no product dimensions, clearances or fabrication information. Original artwork is available under CC BY 4.0. Third-party references retain their own terms.

Entry JSON · Entry Markdown · Last editorial update: 13 October 2026