Circuit breaker
A switching device that can interrupt a circuit, with specified fault-interruption capability.
An independently authored application reference. The drawing shows the named function or circuit relationship; use the project legend and selected equipment documentation for its drafting form and connections.
Browse this installation focusIn plain English
Reports that the removable breaker is outside its normal connected operating position.
In a switchgear control schematic, the bay controller compares independent status contacts before displaying a position or allowing another operation. The signal labels explain which physical state each contact represents. For this reference, the drawing identifies “Withdrawal detection” at the input and “Withdrawn-element indication” at the output. Withdrawal and safe access are separate conditions.
Start at the named input: Withdrawal detection. Identify its source device or document and the state represented on the drawing. Follow the named output: Withdrawn-element indication. Cross-reference its destination and separate the command from confirmation that the equipment responded.
Read the source: Masterclad medium-voltage switchgear: circuit-breaker section interlocks
Reports that the removable breaker is outside its normal connected operating position. Breaker status indications describe the operating mechanism, the removable truck or the health of a supporting system. These signals are related but are not interchangeable: an open breaker can still have its truck connected to live bus contacts.
In a switchgear control schematic, the bay controller compares independent status contacts before displaying a position or allowing another operation. The signal labels explain which physical state each contact represents. For this reference, the drawing identifies “Withdrawal detection” at the input and “Withdrawn-element indication” at the output. Withdrawal and safe access are separate conditions.
Keep contact reference conditions, terminal numbers and interpretation logic together. Distinguish a mechanically operated indication from a measured current or voltage condition. The functional block is an independent explanation of this named application. Equipment-specific ratings, terminal connections and operating conditions must be established in the project documentation.
Withdrawal and safe access are separate conditions. This reference describes the named application; it does not establish a new IEC graphical symbol, an ANSI device-function number or an exact manufacturer connection diagram.
These public references support the explanation and provide further detail. Their graphics and downloadable files remain with their publishers.
Public technical context for breaker position and status interfaces. Breaker control, mechanism, position contacts, racking interlocks and test interfaces. The application text and educational graphic are independently authored; the publisher does not certify this representation.
This illustration was authored independently by Elora Grid to explain the concept. It is not reproduced from a customer drawing, an official standard graphic or a manufacturer CAD file. Its correspondence to an exact IEC or IEEE symbol identifier has not been certified.
SVG and DXF downloads contain this original artwork. Original artwork is available under CC BY 4.0. Third-party references retain their own terms.
Elora Grid helps electrical teams work with drawings, specifications and equipment information. Explore the drafting workflow or join the early-access waitlist.