Functional block · CSBBA

Cable sheath both-end bonding arrangement

Functional block · Switchyards

An independently authored application reference. The drawing shows the named function or circuit relationship; use the project legend and selected equipment documentation for its drafting form and connections.

Browse this installation focus

In plain English

What this block does

Shows the assigned earth bonds at both ends of the documented cable sheath circuit.

A simple example

In a switchyard arrangement, the earthing references help connect each primary equipment structure and surge-protection device to the correct earth-grid interface. Separate details show actual joints, sizes and installation routes. For this reference, the drawing identifies “Cable sheath ends” at the input and “Earth bonds at both ends” at the output. Circulating sheath currents require assessment.

Cable sheath endsCSBBAEarth bonds at both ends
A reading guide. The entry's original illustration and input/output facts describe this application.

What the drawings help you do

Start at the named input: Cable sheath ends. Identify its source device or document and the state represented on the drawing. Follow the named output: Earth bonds at both ends. Cross-reference its destination and separate the command from confirmation that the equipment responded.

Input
Cable sheath ends
Output
Earth bonds at both ends
Application reference
An explanation of a named drawing function or circuit relationship; the project documents define the equipment and its connections.

Read the source: Earthing connections

Schematic · CSBBACable sheath both-end bonding arrangement: original educational illustration
Original educational illustrationSee source and graphic notes

What it represents

Shows the assigned earth bonds at both ends of the documented cable sheath circuit. Earthing and lightning interfaces identify the connections between equipment metalwork, primary protection devices and the station earthing network. Their electrical purpose differs from their physical conductor route or electrode geometry.

In a switchyard arrangement, the earthing references help connect each primary equipment structure and surge-protection device to the correct earth-grid interface. Separate details show actual joints, sizes and installation routes. For this reference, the drawing identifies “Cable sheath ends” at the input and “Earth bonds at both ends” at the output. Circulating sheath currents require assessment.

Name every connected item and the earthing design reference. The illustrative connection does not establish touch or step voltages, conductor sizing, lightning coverage or safe working conditions. The functional block is an independent explanation of this named application. Equipment-specific ratings, terminal connections and operating conditions must be established in the project documentation.

How to read it

  • Start at the named input: Cable sheath ends. Identify its source device or document and the state represented on the drawing.
  • Follow the named output: Earth bonds at both ends. Cross-reference its destination and separate the command from confirmation that the equipment responded.
  • Circulating sheath currents require assessment.
  • Name every connected item and the earthing design reference. The illustrative connection does not establish touch or step voltages, conductor sizing, lightning coverage or safe working conditions.

Information to show or reference

  • Label the source and connection reference for cable sheath ends.
  • Identify the destination and defined state of earth bonds at both ends.
  • Record the equipment or control-document revision supporting this functional block.
  • Check this application limit in the project design: Circulating sheath currents require assessment.

A distinction that matters

Circulating sheath currents require assessment. This reference describes the named application; it does not establish a new IEC graphical symbol, an ANSI device-function number or an exact manufacturer connection diagram.

Sources you can follow

These public references support the explanation and provide further detail. Their graphics and downloadable files remain with their publishers.

Earthing connections

Public technical context for switchyard earthing and lightning interfaces. Protective earthing, bonding and earth-electrode interfaces. The application text and educational graphic are independently authored; the publisher does not certify this representation.

Schneider Electric, Electrical Installation Guide · Public reference checked 28 October 2026 · Link only

About this graphic

This illustration was authored independently by Elora Grid to explain the concept. It is not reproduced from a customer drawing, an official standard graphic or a manufacturer CAD file. Its correspondence to an exact IEC or IEEE symbol identifier has not been certified.

SVG and DXF downloads contain this original artwork. Original artwork is available under CC BY 4.0. Third-party references retain their own terms.

Entry JSON · Entry Markdown · Last editorial update: 3 November 2026