Functional block · DMII

Disconnector motor-control isolation interface

Functional block · Switchyards

An independently authored application reference. The drawing shows the named function or circuit relationship; use the project legend and selected equipment documentation for its drafting form and connections.

Browse this installation focus

In plain English

What this block does

Marks the assigned separation of the electric drive control supply.

A simple example

In a switchyard bay, a bus selector can use a different physical construction from a line disconnector. Each device still needs an identified operating mechanism, position indication and interlocking interface. For this reference, the drawing identifies “Drive supply isolation device” at the input and “Motor-control isolation boundary” at the output. Control isolation does not establish primary isolation.

Drive supply isolation deviceDMIIMotor-control isolation boundary
A reading guide. The entry's original illustration and input/output facts describe this application.

What the drawings help you do

Start at the named input: Drive supply isolation device. Identify its source device or document and the state represented on the drawing. Follow the named output: Motor-control isolation boundary. Cross-reference its destination and separate the command from confirmation that the equipment responded.

Input
Drive supply isolation device
Output
Motor-control isolation boundary
Application reference
An explanation of a named drawing function or circuit relationship; the project documents define the equipment and its connections.

Read the source: Disconnectors and earthing switches

Schematic · DMIIDisconnector motor-control isolation interface: original educational illustration
Original educational illustrationSee source and graphic notes

What it represents

Marks the assigned separation of the electric drive control supply. Disconnector and earthing references identify different mechanical constructions and connection duties within a yard. The primary diagram shows which conductors are joined or earthed; the equipment drawing explains how its contacts and supports move.

In a switchyard bay, a bus selector can use a different physical construction from a line disconnector. Each device still needs an identified operating mechanism, position indication and interlocking interface. For this reference, the drawing identifies “Drive supply isolation device” at the input and “Motor-control isolation boundary” at the output. Control isolation does not establish primary isolation.

The construction name does not establish load-breaking capability, short-circuit making duty or operating permission. Verify these properties in the selected equipment data and the station interlocking scheme. The functional block is an independent explanation of this named application. Equipment-specific ratings, terminal connections and operating conditions must be established in the project documentation.

How to read it

  • Start at the named input: Drive supply isolation device. Identify its source device or document and the state represented on the drawing.
  • Follow the named output: Motor-control isolation boundary. Cross-reference its destination and separate the command from confirmation that the equipment responded.
  • Control isolation does not establish primary isolation.
  • The construction name does not establish load-breaking capability, short-circuit making duty or operating permission. Verify these properties in the selected equipment data and the station interlocking scheme.

Information to show or reference

  • Label the source and connection reference for drive supply isolation device.
  • Identify the destination and defined state of motor-control isolation boundary.
  • Record the equipment or control-document revision supporting this functional block.
  • Check this application limit in the project design: Control isolation does not establish primary isolation.

A distinction that matters

Control isolation does not establish primary isolation. This reference describes the named application; it does not establish a new IEC graphical symbol, an ANSI device-function number or an exact manufacturer connection diagram.

Sources you can follow

These public references support the explanation and provide further detail. Their graphics and downloadable files remain with their publishers.

Disconnectors and earthing switches

Public technical context for disconnector and earthing applications. Disconnector construction, earthing switches and operating mechanisms. The application text and educational graphic are independently authored; the publisher does not certify this representation.

Siemens Energy · Public reference checked 3 November 2026 · Link only

About this graphic

This illustration was authored independently by Elora Grid to explain the concept. It is not reproduced from a customer drawing, an official standard graphic or a manufacturer CAD file. Its correspondence to an exact IEC or IEEE symbol identifier has not been certified.

SVG and DXF downloads contain this original artwork. Original artwork is available under CC BY 4.0. Third-party references retain their own terms.

Entry JSON · Entry Markdown · Last editorial update: 3 November 2026