IEC · Q021327

Timed-operation qualifier

A timed-operation qualifier identifies operation influenced by the documented timing function.

IEC · Timed-operation qualifier

Autodesk IEC-60617 Symbol Preview — Operating-device and function qualifiers; vendor family reference, not certified IEC geometry or database identifier.

Shown as an independently authored educational illustration. Use the cited publication and drawing legend to verify the required drafting form.

Schematic · Q021327Timed-operation qualifier: original educational illustration
Original educational illustrationNot to scale · See source and graphic notes

What it represents

A timed-operation qualifier identifies operation influenced by the documented timing function. A timing relationship describes when an action follows an initiating event. It does not decide whether the timing continues after the input disappears or how the function resets.

Document the input transition, the timed output and the intended timing mode. The main contact or actuator representation still supplies the resulting state.

How to read it

  • State the trigger, timing mode and reset condition separately.
  • A generic timing indication does not distinguish on-delay, off-delay or pulse operation.

Information to show or reference

  • Identify the associated device, circuit or diagram boundary.
  • State the trigger, timing mode and reset condition separately.
  • Cross-reference the equipment data, terminal mapping or operating-state legend needed to interpret the form.

A distinction that matters

A generic timing indication does not distinguish on-delay, off-delay or pulse operation.

Sources you can follow

These public references support the explanation and provide further detail. Their graphics and downloadable files remain with their publishers.

Autodesk IEC-60617 preview: Operating-device and function qualifiers

Official public publisher family name and reference context; vendor identifiers and graphics are distinct from licensed IEC database content.

Autodesk · Public reference checked 14 October 2026 · Link only

About this graphic

This illustration was authored independently by Elora Grid to explain the concept. It is not reproduced from a customer drawing, an official standard graphic or a manufacturer CAD file. Its correspondence to an exact IEC or IEEE symbol identifier has not been certified.

SVG and DXF downloads contain this original artwork. DXF uses unscaled drawing units; a GA envelope supplies no product dimensions, clearances or fabrication information. Original artwork is available under CC BY 4.0. Third-party references retain their own terms.

Entry JSON · Entry Markdown · Last editorial update: 14 October 2026

Put the reference into a drawing workflow.

Elora Grid helps electrical teams work with drawings, specifications and equipment information. Explore the drafting workflow or join the early-access waitlist.