Functional block · MSAM

Microgrid sheddable-load availability monitor

Functional block · Microgrids

An independently authored application reference. The drawing shows the named function or circuit relationship; use the project legend and selected equipment documentation for its drafting form and connections.

Browse this installation focus

In plain English

What this block does

Tracks which assigned load groups are presently connected and available for controlled reduction.

A simple example

In a microgrid island, the controller can disconnect lower-priority loads when a source is lost and later request restoration when the documented reserve and stability conditions permit it. For this reference, the drawing identifies “Load connection and control states” at the input and “Available shedding capacity” at the output. Unavailable control paths reduce effective capacity.

Load connection and controlstatesMSAMAvailable shedding capacity
A reading guide. The entry's original illustration and input/output facts describe this application.

What the drawings help you do

Start at the named input: Load connection and control states. Identify its source device or document and the state represented on the drawing. Follow the named output: Available shedding capacity. Cross-reference its destination and separate the command from confirmation that the equipment responded.

Input
Load connection and control states
Output
Available shedding capacity
Application reference
An explanation of a named drawing function or circuit relationship; the project documents define the equipment and its connections.

Read the source: Avista Shared Energy Economy microgrid protection and control case study

Schematic · MSAMMicrogrid sheddable-load availability monitor: original educational illustration
Original educational illustrationSee source and graphic notes

What it represents

Tracks which assigned load groups are presently connected and available for controlled reduction. Load management balances the available electrical supply against the loads that remain connected. Shedding, restoration, priority and proof of disconnection are separate control functions and should remain traceable to individual load groups.

In a microgrid island, the controller can disconnect lower-priority loads when a source is lost and later request restoration when the documented reserve and stability conditions permit it. For this reference, the drawing identifies “Load connection and control states” at the input and “Available shedding capacity” at the output. Unavailable control paths reduce effective capacity.

Identify each load group, priority, measured contribution and feedback. Shedding amounts, operating times and restoration conditions require the approved power-management design and the actual connected-load data. The functional block is an independent explanation of this named application. Equipment-specific ratings, terminal connections and operating conditions must be established in the project documentation.

How to read it

  • Start at the named input: Load connection and control states. Identify its source device or document and the state represented on the drawing.
  • Follow the named output: Available shedding capacity. Cross-reference its destination and separate the command from confirmation that the equipment responded.
  • Unavailable control paths reduce effective capacity.
  • Identify each load group, priority, measured contribution and feedback. Shedding amounts, operating times and restoration conditions require the approved power-management design and the actual connected-load data.

Information to show or reference

  • Label the source and connection reference for load connection and control states.
  • Identify the destination and defined state of available shedding capacity.
  • Record the equipment or control-document revision supporting this functional block.
  • Check this application limit in the project design: Unavailable control paths reduce effective capacity.

A distinction that matters

Unavailable control paths reduce effective capacity. This reference describes the named application; it does not establish a new IEC graphical symbol, an ANSI device-function number or an exact manufacturer connection diagram.

Sources you can follow

These public references support the explanation and provide further detail. Their graphics and downloadable files remain with their publishers.

Avista Shared Energy Economy microgrid protection and control case study

Public technical context for microgrid load shedding and restoration. Storage, protection, black start, load restoration and coordinated island operation. The application text and educational graphic are independently authored; the publisher does not certify this representation.

SEL · Public reference checked 3 November 2026 · Link only

About this graphic

This illustration was authored independently by Elora Grid to explain the concept. It is not reproduced from a customer drawing, an official standard graphic or a manufacturer CAD file. Its correspondence to an exact IEC or IEEE symbol identifier has not been certified.

SVG and DXF downloads contain this original artwork. Original artwork is available under CC BY 4.0. Third-party references retain their own terms.

Entry JSON · Entry Markdown · Last editorial update: 3 November 2026

Put the reference into a drawing workflow.

Elora Grid helps electrical teams work with drawings, specifications and equipment information. Explore the drafting workflow or join the early-access waitlist.

Explore drafting