Contactor
An electrically operated switching device commonly used for repeated switching duties.
An independently authored application reference. The drawing shows the named function or circuit relationship; use the project legend and selected equipment documentation for its drafting form and connections.
Browse this installation focusIn plain English
Suppresses an automatic restart under the documented post-trip or supply-return condition.
In a switchroom motor-control panel, a ventilation motor can receive an automatic start request while a local selector and the motor protection determine whether the feeder is available. For this reference, the drawing identifies “Trip and supply-return status” at the input and “Restart inhibit” at the output. Restart permission must follow the operating philosophy.
Start at the named input: Trip and supply-return status. Identify its source device or document and the state represented on the drawing. Follow the named output: Restart inhibit. Cross-reference its destination and separate the command from confirmation that the equipment responded.
Read the source: SEL-710 motor protection and control
Suppresses an automatic restart under the documented post-trip or supply-return condition. A motor feeder combines switching, motor protection and an operating command. Starting permission, running feedback and protection trip are different signals even where one relay or controller processes all of them.
In a switchroom motor-control panel, a ventilation motor can receive an automatic start request while a local selector and the motor protection determine whether the feeder is available. For this reference, the drawing identifies “Trip and supply-return status” at the input and “Restart inhibit” at the output. Restart permission must follow the operating philosophy.
Link the motor tag to its contactor, protective device and process permissives. The control diagram must identify stop priority, feedback and restart philosophy without supplying unverified settings. The functional block is an independent explanation of this named application. Equipment-specific ratings, terminal connections and operating conditions must be established in the project documentation.
Restart permission must follow the operating philosophy. This reference describes the named application; it does not establish a new IEC graphical symbol, an ANSI device-function number or an exact manufacturer connection diagram.
These public references support the explanation and provide further detail. Their graphics and downloadable files remain with their publishers.
Public technical context for motor-feeder control interfaces. Motor feeder thermal, starting and control functions. The application text and educational graphic are independently authored; the publisher does not certify this representation.
This illustration was authored independently by Elora Grid to explain the concept. It is not reproduced from a customer drawing, an official standard graphic or a manufacturer CAD file. Its correspondence to an exact IEC or IEEE symbol identifier has not been certified.
SVG and DXF downloads contain this original artwork. Original artwork is available under CC BY 4.0. Third-party references retain their own terms.
Elora Grid helps electrical teams work with drawings, specifications and equipment information. Explore the drafting workflow or join the early-access waitlist.