Functional block · SCAI

Station charger AC-failure indication

Functional block · Substations

An independently authored application reference. The drawing shows the named function or circuit relationship; use the project legend and selected equipment documentation for its drafting form and connections.

Browse this installation focus

In plain English

What this block does

Reports loss of the assigned charger input supply while distinguishing the available battery path.

A simple example

In a substation control building, the battery can support breaker trip circuits while the charger AC supply is unavailable. Supervision must identify whether the charger, battery or a downstream feeder is affected. For this reference, the drawing identifies “Charger AC input health” at the input and “Charger AC-failure alarm” at the output. Battery support may remain available.

Charger AC input healthSCAICharger AC-failure alarm
A reading guide. The entry's original illustration and input/output facts describe this application.

What the drawings help you do

Start at the named input: Charger AC input health. Identify its source device or document and the state represented on the drawing. Follow the named output: Charger AC-failure alarm. Cross-reference its destination and separate the command from confirmation that the equipment responded.

Input
Charger AC input health
Output
Charger AC-failure alarm
Application reference
An explanation of a named drawing function or circuit relationship; the project documents define the equipment and its connections.

Read the source: MicroGenius S2/S4 battery charger technical manual

Schematic · SCAIStation charger AC-failure indication: original educational illustration
Original educational illustrationSee source and graphic notes

What it represents

Reports loss of the assigned charger input supply while distinguishing the available battery path. A station battery system supplies protection, control and other assigned DC loads through a documented charger and distribution arrangement. Charger output, battery contribution and load distribution are related but separately monitored paths.

In a substation control building, the battery can support breaker trip circuits while the charger AC supply is unavailable. Supervision must identify whether the charger, battery or a downstream feeder is affected. For this reference, the drawing identifies “Charger AC input health” at the input and “Charger AC-failure alarm” at the output. Battery support may remain available.

Identify every source, protective device, isolation boundary and return. Battery capacity, DC fault duty, charging settings and ventilation require the selected battery-system design; illustrative circuits do not establish autonomy. The functional block is an independent explanation of this named application. Equipment-specific ratings, terminal connections and operating conditions must be established in the project documentation.

How to read it

  • Start at the named input: Charger AC input health. Identify its source device or document and the state represented on the drawing.
  • Follow the named output: Charger AC-failure alarm. Cross-reference its destination and separate the command from confirmation that the equipment responded.
  • Battery support may remain available.
  • Identify every source, protective device, isolation boundary and return. Battery capacity, DC fault duty, charging settings and ventilation require the selected battery-system design; illustrative circuits do not establish autonomy.

Information to show or reference

  • Label the source and connection reference for charger ac input health.
  • Identify the destination and defined state of charger ac-failure alarm.
  • Record the equipment or control-document revision supporting this functional block.
  • Check this application limit in the project design: Battery support may remain available.

A distinction that matters

Battery support may remain available. This reference describes the named application; it does not establish a new IEC graphical symbol, an ANSI device-function number or an exact manufacturer connection diagram.

Sources you can follow

These public references support the explanation and provide further detail. Their graphics and downloadable files remain with their publishers.

MicroGenius S2/S4 battery charger technical manual

Public technical context for station battery and charger distribution. Battery charging modes, DC distribution interfaces and charger alarms. The application text and educational graphic are independently authored; the publisher does not certify this representation.

SENS · Public reference checked 3 November 2026 · Link only

About this graphic

This illustration was authored independently by Elora Grid to explain the concept. It is not reproduced from a customer drawing, an official standard graphic or a manufacturer CAD file. Its correspondence to an exact IEC or IEEE symbol identifier has not been certified.

SVG and DXF downloads contain this original artwork. Original artwork is available under CC BY 4.0. Third-party references retain their own terms.

Entry JSON · Entry Markdown · Last editorial update: 3 November 2026