Functional block · TMOA

Transformer main-tank oil-level alarm

Functional block · Substations

An independently authored application reference. The drawing shows the named function or circuit relationship; use the project legend and selected equipment documentation for its drafting form and connections.

Browse this installation focus

In plain English

What this block does

Reports the documented low or abnormal oil-level condition in the main tank system.

A simple example

In a substation transformer bay, a protection panel receives winding-current measurements and equipment alarm contacts. An operator can then distinguish an electrical protection operation from a cooling-system or physical-condition alarm. For this reference, the drawing identifies “Main oil-level contact” at the input and “Main-tank level alarm” at the output. Oil level varies with operating conditions.

Main oil-level contactTMOAMain-tank level alarm
A reading guide. The entry's original illustration and input/output facts describe this application.

What the drawings help you do

Start at the named input: Main oil-level contact. Identify its source device or document and the state represented on the drawing. Follow the named output: Main-tank level alarm. Cross-reference its destination and separate the command from confirmation that the equipment responded.

Input
Main oil-level contact
Output
Main-tank level alarm
Application reference
An explanation of a named drawing function or circuit relationship; the project documents define the equipment and its connections.

Read the source: SEL-487E transformer protection relay

Schematic · TMOATransformer main-tank oil-level alarm: original educational illustration
Original educational illustrationSee source and graphic notes

What it represents

Reports the documented low or abnormal oil-level condition in the main tank system. Transformer monitoring interfaces connect physical sensors and protection calculations to the station's alarms and trip logic. Temperature, oil, gas, pressure and electrical measurements indicate different conditions and require separate interpretation.

In a substation transformer bay, a protection panel receives winding-current measurements and equipment alarm contacts. An operator can then distinguish an electrical protection operation from a cooling-system or physical-condition alarm. For this reference, the drawing identifies “Main oil-level contact” at the input and “Main-tank level alarm” at the output. Oil level varies with operating conditions.

Identify the sensor or calculation, its monitored zone and its assigned response. Alarm and trip thresholds, sensor fitting and protection settings belong to the selected transformer documentation and the approved protection design. The functional block is an independent explanation of this named application. Equipment-specific ratings, terminal connections and operating conditions must be established in the project documentation.

How to read it

  • Start at the named input: Main oil-level contact. Identify its source device or document and the state represented on the drawing.
  • Follow the named output: Main-tank level alarm. Cross-reference its destination and separate the command from confirmation that the equipment responded.
  • Oil level varies with operating conditions.
  • Identify the sensor or calculation, its monitored zone and its assigned response. Alarm and trip thresholds, sensor fitting and protection settings belong to the selected transformer documentation and the approved protection design.

Information to show or reference

  • Label the source and connection reference for main oil-level contact.
  • Identify the destination and defined state of main-tank level alarm.
  • Record the equipment or control-document revision supporting this functional block.
  • Check this application limit in the project design: Oil level varies with operating conditions.

A distinction that matters

Oil level varies with operating conditions. This reference describes the named application; it does not establish a new IEC graphical symbol, an ANSI device-function number or an exact manufacturer connection diagram.

Sources you can follow

These public references support the explanation and provide further detail. Their graphics and downloadable files remain with their publishers.

SEL-487E transformer protection relay

Public technical context for transformer protection and monitoring interfaces. Transformer protection, monitoring and measurement interfaces. The application text and educational graphic are independently authored; the publisher does not certify this representation.

SEL · Public reference checked 3 November 2026 · Link only

About this graphic

This illustration was authored independently by Elora Grid to explain the concept. It is not reproduced from a customer drawing, an official standard graphic or a manufacturer CAD file. Its correspondence to an exact IEC or IEEE symbol identifier has not been certified.

SVG and DXF downloads contain this original artwork. Original artwork is available under CC BY 4.0. Third-party references retain their own terms.

Entry JSON · Entry Markdown · Last editorial update: 3 November 2026

Put the reference into a drawing workflow.

Elora Grid helps electrical teams work with drawings, specifications and equipment information. Explore the drafting workflow or join the early-access waitlist.

Explore drafting