Voltage transformer
A transformer providing a voltage signal for metering or protection.
An independently authored application reference. The drawing shows the named function or circuit relationship; use the project legend and selected equipment documentation for its drafting form and connections.
Browse this installation focusIn plain English
Preserves the identified phase sequence through the secondary voltage measurement circuit.
In a substation bay, one voltage circuit can feed protection while a separately identified winding supplies metering. A voltage-selection circuit must make clear which bus or line measurement is being used. For this reference, the drawing identifies “Phase-labelled VT signals” at the input and “Consistent phase rotation” at the output. Labels need verification against the connection diagram.
Start at the named input: Phase-labelled VT signals. Identify its source device or document and the state represented on the drawing. Follow the named output: Consistent phase rotation. Cross-reference its destination and separate the command from confirmation that the equipment responded.
Read the source: Indoor current and voltage transformers
Preserves the identified phase sequence through the secondary voltage measurement circuit. A voltage-transformer secondary arrangement connects a defined primary voltage measurement to protection, metering or control inputs. Winding identity, fuse protection and the voltage reference must remain visible across the drawing.
In a substation bay, one voltage circuit can feed protection while a separately identified winding supplies metering. A voltage-selection circuit must make clear which bus or line measurement is being used. For this reference, the drawing identifies “Phase-labelled VT signals” at the input and “Consistent phase rotation” at the output. Labels need verification against the connection diagram.
Show the primary measurement point, secondary connection, protective devices and relay reference. A missing measurement can resemble a real system disturbance unless the voltage-circuit health is supervised appropriately. The functional block is an independent explanation of this named application. Equipment-specific ratings, terminal connections and operating conditions must be established in the project documentation.
Labels need verification against the connection diagram. This reference describes the named application; it does not establish a new IEC graphical symbol, an ANSI device-function number or an exact manufacturer connection diagram.
These public references support the explanation and provide further detail. Their graphics and downloadable files remain with their publishers.
Public technical context for voltage-transformer secondary arrangements. Current and voltage measurement transformers and their secondary interfaces. The application text and educational graphic are independently authored; the publisher does not certify this representation.
This illustration was authored independently by Elora Grid to explain the concept. It is not reproduced from a customer drawing, an official standard graphic or a manufacturer CAD file. Its correspondence to an exact IEC or IEEE symbol identifier has not been certified.
SVG and DXF downloads contain this original artwork. Original artwork is available under CC BY 4.0. Third-party references retain their own terms.
Elora Grid helps electrical teams work with drawings, specifications and equipment information. Explore the drafting workflow or join the early-access waitlist.