ABB

REF615 ANSI 5.1 configuration L CAD drawings & downloads

REF615 ANSI 5.1 configuration L: ABB manufacturer DWG resource, document 2RCA025328_REF615_CONF_L, revision A. Use it to coordinate the selected primary-equipment or protection-panel arrangement.

DWG · 1 listed file · Source checked 2026-11-03

Download files

Original files · Hosted here

2RCA025328 REF615 conf L

DWG · 116 KB · Rev A

Original filename: 2RCA025328_REF615_conf_L.dwg

Original DWG drawing for REF615 ANSI 5.1 configuration L; ABB document 2RCA025328_REF615_CONF_L / dwg

Need another model or format?

Request manufacturer CAD

REF615 ANSI 5.1 configuration L

Enter your email and our team can request the manufacturer's drawings for this equipment.

Sent to our team for manufacturer follow-up. Availability and timing will be confirmed by email. Privacy policy

Equipment and file summary

Equipment / resource
REF615 ANSI 5.1 configuration L
Manufacturer
ABB
Resource type
Named drawing reference
Manufacturer drawing
2RCA025328_REF615_CONF_L / dwg
Listed file formats
DWG
Listed files
1
Available previews
1 drawing previews
Recorded revisions
A
Source checked
2026-11-03
Download access
Email registration for site downloads; official source links are also available

2D drawing preview

Preview rendered from the original CAD drawing
2RCA025328 REF615 conf L: CAD drawing preview
Zoom 100%
Download original drawing ↓

Explore the model in 3D

You can preview the supplied 2D drawings here. Use the original file links above or request a matching model for your exact configuration.

Request manufacturer CAD

REF615 ANSI 5.1 configuration L

Enter your email and our team can request the manufacturer's drawings for this equipment.

Sent to our team for manufacturer follow-up. Availability and timing will be confirmed by email. Privacy policy

Which file should I choose?

Use 2RCA025328_REF615_conf_L.dwg for REF615 ANSI 5.1 configuration L. DWG is the supplied drawing format; the preview shows the source sheet. A matching STEP model is not included. Match ABB document 2RCA025328_REF615_CONF_L revision A when checking a replacement.

What is included?

REF615 ANSI 5.1 configuration L lists 1 file route from ABB. Drawing content: protection and control relay, manufacturer drawing.

Checked source file: 2RCA025328_REF615_conf_L.dwg · 116 KB · DWG.

Before using it

  • Match the configuration named “REF615 ANSI 5.1 configuration L”; terminal direction, mounting version and pole options can change the outline.
  • Use ABB document 2RCA025328_REF615_CONF_L, revision A, to check the mounting and connection details before placing this item in the assembly.
  • Read the actual dimensions and notes in 2RCA025328_REF615_conf_L.dwg; a 2D outline does not provide a complete 3D assembly.

In plain English

What the equipment does

A relay uses an electrical input or measured condition to change its contacts or output. This lets one circuit pass a command or indication to another.

A simple example

When coordinating REF615 ANSI 5.1 configuration L in substations, place the documented arrangement beside the adjacent equipment and compare its fixing and connection access with the source drawing.

Questions about this resource

Which ABB source identifies REF615 ANSI 5.1 configuration L?

The acquired file is 2RCA025328_REF615_conf_L.dwg, document 2RCA025328_REF615_CONF_L, revision A. The manufacturer source and pinned original link appear below.

Does the preview establish installation clearances?

No. Use the installation requirements for REF615 ANSI 5.1 configuration L and the selected assembly to reserve cable and service access.

Equipment references and drawing guides

Related GA equipment

Electrical drawing guides →

Use in a project

Sources & versions

Original publisher: ABB. Source checked 2026-11-03. Original bytes are preserved; file links and document references identify the source.

Manufacturer
ABB
Resource
Named drawing reference
Formats
DWG
Regional source coverage
Global

Manufacturer library discovery does not establish regional certification. Match the listed frame, terminal arrangement and accessories to the project.

Verified file identity

2RCA025328_REF615_conf_L.dwg · DWG · 118,466 bytes

SHA-256: 507be788029bb6ba939dc71bc5a44de133829f70a43854b88d41ac6937616304

More protection & metering · More ABB drawings · Request other equipment