ITSCE 601812751
DXF · 404 KB · Rev E
Original filename: ITSCE_601812751.dxf
Original DXF drawing for S3 4p Residual current release RC 211-212/3 Bottom mounting Front extended terminals; ABB document ITSCE-601812751
ABB
S3 4p Residual current release RC 211-212/3 Bottom mounting Front extended terminals: ABB manufacturer DXF resource, document ITSCE-601812751, revision E. Use it to coordinate the breaker, switch or accessory arrangement in the switchgear assembly.
DXF · 1 listed file · Source checked 2026-11-03
DXF · 404 KB · Rev E
Original filename: ITSCE_601812751.dxf
Original DXF drawing for S3 4p Residual current release RC 211-212/3 Bottom mounting Front extended terminals; ABB document ITSCE-601812751
You can preview the supplied 2D drawings here. Use the original file links above or request a matching model for your exact configuration.
Use ITSCE_601812751.dxf for S3 4p Residual current release RC 211-212/3 Bottom mounting Front extended terminals. DXF is the supplied drawing format; the preview shows the source sheet. A matching STEP model is not included. Match ABB document ITSCE-601812751 revision E when checking a replacement.
S3 4p Residual current release RC 211-212/3 Bottom mounting Front extended terminals lists 1 file route from ABB. Drawing content: circuit breaker or mounting accessory, manufacturer drawing.
Checked source file: ITSCE_601812751.dxf · 404 KB · DXF.
In plain English
A residual-current device compares the current leaving a circuit with the current returning. A difference can indicate current flowing along an unintended path, causing the device to trip. An RCBO also provides overcurrent protection.
When coordinating S3 4p Residual current release RC 211-212/3 Bottom mounting Front extended terminals in switchgear, place the documented arrangement beside the adjacent equipment and compare its fixing and connection access with the source drawing.
The acquired file is ITSCE_601812751.dxf, document ITSCE-601812751, revision E. The manufacturer source and pinned original link appear below.
No. Use the installation requirements for S3 4p Residual current release RC 211-212/3 Bottom mounting Front extended terminals and the selected assembly to reserve cable and service access.
Original publisher: ABB. Source checked 2026-11-03. Original bytes are preserved; file links and document references identify the source.
Manufacturer library discovery does not establish regional certification. Match the listed frame, terminal arrangement and accessories to the project.
ITSCE_601812751.dxf · DXF · 413,302 bytes
SHA-256: 60b9e151212156351f67f128e82fa1acc8cca9b0068fe8b986d3fc6c739ec7dfMore breakers & accessories · More ABB drawings · Request other equipment