Functional block · DCIC

Digital-secondary channel identity cross-reference

Functional block · Substations

An independently authored application reference. The drawing shows the named function or circuit relationship; use the project legend and selected equipment documentation for its drafting form and connections.

Browse this installation focus

In plain English

What this block does

Links the drawing channel names to the selected configuration and equipment documentation.

A simple example

In a digital substation bay, a merging unit digitizes local measurements and a protective relay subscribes to the assigned data stream. The command return path and communication-health indications are drawn separately. For this reference, the drawing identifies “Drawing signal identifiers” at the input and “Configuration channel references” at the output. Configuration revision must match the installation.

Drawing signal identifiersDCICConfiguration channel references
A reading guide. The entry's original illustration and input/output facts describe this application.

What the drawings help you do

Start at the named input: Drawing signal identifiers. Identify its source device or document and the state represented on the drawing. Follow the named output: Configuration channel references. Cross-reference its destination and separate the command from confirmation that the equipment responded.

Input
Drawing signal identifiers
Output
Configuration channel references
Application reference
An explanation of a named drawing function or circuit relationship; the project documents define the equipment and its connections.

Read the source: Digital secondary systems: Sampled Values

Schematic · DCICDigital-secondary channel identity cross-reference: original educational illustration
Original educational illustrationSee source and graphic notes

What it represents

Links the drawing channel names to the selected configuration and equipment documentation. Digital substation interfaces carry measurements, status and control information between primary equipment and protective devices. Measurement streams, event messages and time synchronization are separate dependencies even when they share an Ethernet network.

In a digital substation bay, a merging unit digitizes local measurements and a protective relay subscribes to the assigned data stream. The command return path and communication-health indications are drawn separately. For this reference, the drawing identifies “Drawing signal identifiers” at the input and “Configuration channel references” at the output. Configuration revision must match the installation.

Identify publisher, subscriber, data meaning and quality handling. Protocol labels alone do not establish protection performance, compatibility or network redundancy; these need the selected system configuration and validation. The functional block is an independent explanation of this named application. Equipment-specific ratings, terminal connections and operating conditions must be established in the project documentation.

How to read it

  • Start at the named input: Drawing signal identifiers. Identify its source device or document and the state represented on the drawing.
  • Follow the named output: Configuration channel references. Cross-reference its destination and separate the command from confirmation that the equipment responded.
  • Configuration revision must match the installation.
  • Identify publisher, subscriber, data meaning and quality handling. Protocol labels alone do not establish protection performance, compatibility or network redundancy; these need the selected system configuration and validation.

Information to show or reference

  • Label the source and connection reference for drawing signal identifiers.
  • Identify the destination and defined state of configuration channel references.
  • Record the equipment or control-document revision supporting this functional block.
  • Check this application limit in the project design: Configuration revision must match the installation.

A distinction that matters

Configuration revision must match the installation. This reference describes the named application; it does not establish a new IEC graphical symbol, an ANSI device-function number or an exact manufacturer connection diagram.

Sources you can follow

These public references support the explanation and provide further detail. Their graphics and downloadable files remain with their publishers.

Digital secondary systems: Sampled Values

Public technical context for digital substation process interfaces. Merging units, sampled measurements, GOOSE, process bus and network redundancy. The application text and educational graphic are independently authored; the publisher does not certify this representation.

SEL · Public reference checked 3 November 2026 · Link only

About this graphic

This illustration was authored independently by Elora Grid to explain the concept. It is not reproduced from a customer drawing, an official standard graphic or a manufacturer CAD file. Its correspondence to an exact IEC or IEEE symbol identifier has not been certified.

SVG and DXF downloads contain this original artwork. Original artwork is available under CC BY 4.0. Third-party references retain their own terms.

Entry JSON · Entry Markdown · Last editorial update: 3 November 2026

Put the reference into a drawing workflow.

Elora Grid helps electrical teams work with drawings, specifications and equipment information. Explore the drafting workflow or join the early-access waitlist.

Explore drafting