Functional block · PCCI

Power-line carrier coupling-capacitor interface

Functional block · Switchyards

An independently authored application reference. The drawing shows the named function or circuit relationship; use the project legend and selected equipment documentation for its drafting form and connections.

Browse this installation focus

In plain English

What this block does

Identifies the coupling boundary between a carrier communication signal and the assigned primary conductor.

A simple example

In a switchyard line bay, carrier-coupling equipment can connect a protection communication terminal to the transmission conductor. Fiber-based protection uses another physical path but still needs named endpoints and channel supervision. For this reference, the drawing identifies “Carrier coupling signal” at the input and “Primary-line carrier connection” at the output. Coupling equipment requires the selected insulation arrangement.

Carrier coupling signalPCCIPrimary-line carrier connection
A reading guide. The entry's original illustration and input/output facts describe this application.

What the drawings help you do

Start at the named input: Carrier coupling signal. Identify its source device or document and the state represented on the drawing. Follow the named output: Primary-line carrier connection. Cross-reference its destination and separate the command from confirmation that the equipment responded.

Input
Carrier coupling signal
Output
Primary-line carrier connection
Application reference
An explanation of a named drawing function or circuit relationship; the project documents define the equipment and its connections.

Read the source: Line traps: power-line carrier communication

Schematic · PCCIPower-line carrier coupling-capacitor interface: original educational illustration
Original educational illustrationSee source and graphic notes

What it represents

Identifies the coupling boundary between a carrier communication signal and the assigned primary conductor. A protection communication interface carries information between circuit ends or couples a communication signal to a primary line. Its signal path is different from the power-current path even when both use part of the same installation.

In a switchyard line bay, carrier-coupling equipment can connect a protection communication terminal to the transmission conductor. Fiber-based protection uses another physical path but still needs named endpoints and channel supervision. For this reference, the drawing identifies “Carrier coupling signal” at the input and “Primary-line carrier connection” at the output. Coupling equipment requires the selected insulation arrangement.

Show each coupling boundary and the intended information direction. Frequency selection, channel performance, insulation duty and protective coordination require the selected communication and primary equipment design. The functional block is an independent explanation of this named application. Equipment-specific ratings, terminal connections and operating conditions must be established in the project documentation.

How to read it

  • Start at the named input: Carrier coupling signal. Identify its source device or document and the state represented on the drawing.
  • Follow the named output: Primary-line carrier connection. Cross-reference its destination and separate the command from confirmation that the equipment responded.
  • Coupling equipment requires the selected insulation arrangement.
  • Show each coupling boundary and the intended information direction. Frequency selection, channel performance, insulation duty and protective coordination require the selected communication and primary equipment design.

Information to show or reference

  • Label the source and connection reference for carrier coupling signal.
  • Identify the destination and defined state of primary-line carrier connection.
  • Record the equipment or control-document revision supporting this functional block.
  • Check this application limit in the project design: Coupling equipment requires the selected insulation arrangement.

A distinction that matters

Coupling equipment requires the selected insulation arrangement. This reference describes the named application; it does not establish a new IEC graphical symbol, an ANSI device-function number or an exact manufacturer connection diagram.

Sources you can follow

These public references support the explanation and provide further detail. Their graphics and downloadable files remain with their publishers.

Line traps: power-line carrier communication

Public technical context for line carrier and protection communication interfaces. Line traps, coupling and power-line carrier communications. The application text and educational graphic are independently authored; the publisher does not certify this representation.

GE Vernova · Public reference checked 3 November 2026 · Link only

About this graphic

This illustration was authored independently by Elora Grid to explain the concept. It is not reproduced from a customer drawing, an official standard graphic or a manufacturer CAD file. Its correspondence to an exact IEC or IEEE symbol identifier has not been certified.

SVG and DXF downloads contain this original artwork. Original artwork is available under CC BY 4.0. Third-party references retain their own terms.

Entry JSON · Entry Markdown · Last editorial update: 3 November 2026

Put the reference into a drawing workflow.

Elora Grid helps electrical teams work with drawings, specifications and equipment information. Explore the drafting workflow or join the early-access waitlist.

Explore drafting