Functional block · SHHA

Switchroom humidity high alarm

Functional block · Switchrooms

An independently authored application reference. The drawing shows the named function or circuit relationship; use the project legend and selected equipment documentation for its drafting form and connections.

Browse this installation focus

In plain English

What this block does

Reports humidity exceeding the defined supervision condition at the monitored location.

A simple example

In a switchroom, water ingress, temperature, humidity and equipment-service alarms can be sent to the station controller with separate point names so an operator can identify the affected area. For this reference, the drawing identifies “Room humidity measurement” at the input and “High-humidity indication” at the output. Relative humidity varies with temperature.

Room humidity measurementSHHAHigh-humidity indication
A reading guide. The entry's original illustration and input/output facts describe this application.

What the drawings help you do

Start at the named input: Room humidity measurement. Identify its source device or document and the state represented on the drawing. Follow the named output: High-humidity indication. Cross-reference its destination and separate the command from confirmation that the equipment responded.

Input
Room humidity measurement
Output
High-humidity indication
Application reference
An explanation of a named drawing function or circuit relationship; the project documents define the equipment and its connections.

Read the source: Ventilation in MV substations

Schematic · SHHASwitchroom humidity high alarm: original educational illustration
Original educational illustrationSee source and graphic notes

What it represents

Reports humidity exceeding the defined supervision condition at the monitored location. Environmental supervision turns measurements or contact states into clearly named room-service indications. A sensor measures a condition; the supervisory function decides whether the assigned alarm or control response is needed.

In a switchroom, water ingress, temperature, humidity and equipment-service alarms can be sent to the station controller with separate point names so an operator can identify the affected area. For this reference, the drawing identifies “Room humidity measurement” at the input and “High-humidity indication” at the output. Relative humidity varies with temperature.

Keep sensor location, alarm thresholds, delay and monitoring coverage in the room-services schedule. An environmental alarm is a diagnostic input, not a complete assessment of electrical equipment condition. The functional block is an independent explanation of this named application. Equipment-specific ratings, terminal connections and operating conditions must be established in the project documentation.

How to read it

  • Start at the named input: Room humidity measurement. Identify its source device or document and the state represented on the drawing.
  • Follow the named output: High-humidity indication. Cross-reference its destination and separate the command from confirmation that the equipment responded.
  • Relative humidity varies with temperature.
  • Keep sensor location, alarm thresholds, delay and monitoring coverage in the room-services schedule. An environmental alarm is a diagnostic input, not a complete assessment of electrical equipment condition.

Information to show or reference

  • Label the source and connection reference for room humidity measurement.
  • Identify the destination and defined state of high-humidity indication.
  • Record the equipment or control-document revision supporting this functional block.
  • Check this application limit in the project design: Relative humidity varies with temperature.

A distinction that matters

Relative humidity varies with temperature. This reference describes the named application; it does not establish a new IEC graphical symbol, an ANSI device-function number or an exact manufacturer connection diagram.

Sources you can follow

These public references support the explanation and provide further detail. Their graphics and downloadable files remain with their publishers.

Ventilation in MV substations

Public technical context for switchroom environmental supervision. Heat removal, condensation and environmental design context. The application text and educational graphic are independently authored; the publisher does not certify this representation.

Schneider Electric · Public reference checked 3 November 2026 · Link only

About this graphic

This illustration was authored independently by Elora Grid to explain the concept. It is not reproduced from a customer drawing, an official standard graphic or a manufacturer CAD file. Its correspondence to an exact IEC or IEEE symbol identifier has not been certified.

SVG and DXF downloads contain this original artwork. Original artwork is available under CC BY 4.0. Third-party references retain their own terms.

Entry JSON · Entry Markdown · Last editorial update: 3 November 2026