Equipment library / Wiring & terminals

Wiring & terminals CAD files: page 113.

16,385 parts in wiring & terminals with drawings, 3D models or manufacturer sources. Search and filter Wiring & terminals

All wiring & terminals

Showing 11,201 to 11,300 of 16,385. Parts with 3D models and drawing previews are listed first.

DILMF14-01(RAC240) — Contactors for Semiconductor Industries acc. to SEMI F47, 380 V 400 V: 12 A, 1 NC, RAC 240: 190 - 240 V 50/60 Hz, Screw terminalsEaton · STEPDILMF14-10(RAC24) — Contactors for Semiconductor Industries acc. to SEMI F47, 380 V 400 V: 12 A, 1 N/O, RAC 24: 24 V 50/60 Hz, Screw terminalsEaton · STEPDILMF14-10(RAC48) — Contactors for Semiconductor Industries acc. to SEMI F47, 380 V 400 V: 12 A, 1 N/O, RAC 48: 42 - 48 V 50/60 Hz, Screw terminalsEaton · STEPDILMF14-10(RAC120) — Contactors for Semiconductor Industries acc. to SEMI F47, 380 V 400 V: 12 A, 1 N/O, RAC 120: 100 - 120 V 50/60 Hz, Screw terminalsEaton · STEPDILMF14-10(RAC240) — Contactors for Semiconductor Industries acc. to SEMI F47, 380 V 400 V: 12 A, 1 N/O, RAC 240: 190 - 240 V 50/60 Hz, Screw terminalsEaton · STEPDILMF17-01(RAC24) — Contactors for Semiconductor Industries acc. to SEMI F47, 380 V 400 V: 18 A, 1 NC, RAC 24: 24 V 50/60 Hz, Screw terminalsEaton · STEPDILMF17-01(RAC48) — Contactors for Semiconductor Industries acc. to SEMI F47, 380 V 400 V: 18 A, 1 NC, RAC 48: 42 - 48 V 50/60 Hz, Screw terminalsEaton · STEPDILMF17-01(RAC120) — Contactors for Semiconductor Industries acc. to SEMI F47, 380 V 400 V: 18 A, 1 NC, RAC 120: 100 - 120 V 50/60 Hz, Screw terminalsEaton · STEPDILMF17-01(RAC240) — Contactors for Semiconductor Industries acc. to SEMI F47, 380 V 400 V: 18 A, 1 NC, RAC 240: 190 - 240 V 50/60 Hz, Screw terminalsEaton · STEPDILMF17-10(RAC24) — Contactors for Semiconductor Industries acc. to SEMI F47, 380 V 400 V: 18 A, 1 N/O, RAC 24: 24 V 50/60 Hz, Screw terminalsEaton · STEPDILMF17-10(RAC48) — Contactors for Semiconductor Industries acc. to SEMI F47, 380 V 400 V: 18 A, 1 N/O, RAC 48: 42 - 48 V 50/60 Hz, Screw terminalsEaton · STEPDILMF17-10(RAC120) — Contactors for Semiconductor Industries acc. to SEMI F47, 380 V 400 V: 18 A, 1 N/O, RAC 120: 100 - 120 V 50/60 Hz, Screw terminalsEaton · STEPDILMF17-10(RAC240) — Contactors for Semiconductor Industries acc. to SEMI F47, 380 V 400 V: 18 A, 1 N/O, RAC 240: 190 - 240 V 50/60 Hz, Screw terminalsEaton · STEPDILMF25-01(RAC24) — Contactors for Semiconductor Industries acc. to SEMI F47, 380 V 400 V: 25 A, 1 NC, RAC 24: 24 V 50/60 Hz, Screw terminalsEaton · STEPDILMF25-01(RAC48) — Contactors for Semiconductor Industries acc. to SEMI F47, 380 V 400 V: 25 A, 1 NC, RAC 48: 42 - 48 V 50/60 Hz, Screw terminalsEaton · STEPDILMF25-01(RAC120) — Contactors for Semiconductor Industries acc. to SEMI F47, 380 V 400 V: 25 A, 1 NC, RAC 120: 100 - 120 V 50/60 Hz, Screw terminalsEaton · STEPDILMF25-01(RAC240) — Contactors for Semiconductor Industries acc. to SEMI F47, 380 V 400 V: 25 A, 1 NC, RAC 240: 190 - 240 V 50/60 Hz, Screw terminalsEaton · STEPDILMF25-10(RAC24) — Contactors for Semiconductor Industries acc. to SEMI F47, 380 V 400 V: 25 A, 1 N/O, RAC 24: 24 V 50/60 Hz, Screw terminalsEaton · STEPDILMF25-10(RAC48) — Contactors for Semiconductor Industries acc. to SEMI F47, 380 V 400 V: 25 A, 1 N/O, RAC 48: 42 - 48 V 50/60 Hz, Screw terminalsEaton · STEPDILMF25-10(RAC120) — Contactors for Semiconductor Industries acc. to SEMI F47, 380 V 400 V: 25 A, 1 N/O, RAC 120: 100 - 120 V 50/60 Hz, Screw terminalsEaton · STEPDILMF25-10(RAC240) — Contactors for Semiconductor Industries acc. to SEMI F47, 380 V 400 V: 25 A, 1 N/O, RAC 240: 190 - 240 V 50/60 Hz, Screw terminalsEaton · STEPDILMF32-01(RAC24) — Contactors for Semiconductor Industries acc. to SEMI F47, 380 V 400 V: 32 A, 1 NC, RAC 24: 24 V 50/60 Hz, Screw terminalsEaton · STEPDILMF32-01(RAC48) — Contactors for Semiconductor Industries acc. to SEMI F47, 380 V 400 V: 32 A, 1 NC, RAC 48: 42 - 48 V 50/60 Hz, Screw terminalsEaton · STEPDILMF32-01(RAC120) — Contactors for Semiconductor Industries acc. to SEMI F47, 380 V 400 V: 32 A, 1 NC, RAC 120: 100 - 120 V 50/60 Hz, Screw terminalsEaton · STEPDILMF32-01(RAC240) — Contactors for Semiconductor Industries acc. to SEMI F47, 380 V 400 V: 32 A, 1 NC, RAC 240: 190 - 240 V 50/60 Hz, Screw terminalsEaton · STEPDILMF32-10(RAC24) — Contactors for Semiconductor Industries acc. to SEMI F47, 380 V 400 V: 32 A, 1 N/O, RAC 24: 24 V 50/60 Hz, Screw terminalsEaton · STEPDILMF32-10(RAC48) — Contactors for Semiconductor Industries acc. to SEMI F47, 380 V 400 V: 32 A, 1 N/O, RAC 48: 42 - 48 V 50/60 Hz, Screw terminalsEaton · STEPDILMF32-10(RAC120) — Contactors for Semiconductor Industries acc. to SEMI F47, 380 V 400 V: 32 A, 1 N/O, RAC 120: 100 - 120 V 50/60 Hz, Screw terminalsEaton · STEPDILMF32-10(RAC240) — Contactors for Semiconductor Industries acc. to SEMI F47, 380 V 400 V: 32 A, 1 N/O, RAC 240: 190 - 240 V 50/60 Hz, Screw terminalsEaton · STEPDMV-160N/1 — Switch-disconnector, DMV, 160 A, 3P + N (solid), Stop Function optional, Without rotary handle and drive shaft, Screw terminalEaton · DWG / STEPDMV-160N/3 — Switch-disconnector, DMV, 160 A, 3 pole, Stop Function optional, Without rotary handle and drive shaft, Screw terminal, drilling dimension 6,5 mmEaton · DWG / STEPDMV-160N/4 — Switch-disconnector, DMV, 160 A, 4 pole, Stop Function optional, Without rotary handle and drive shaft, Screw terminal, drilling dimension 6,5 mmEaton · DWG / STEPEMS-DO-T-9-24VDC — DOL starter, 24 V DC, 1,5 - 6,5 (AC-53a), 9 (AC-51) A, Push in terminals, PTB 13 ATEX 3003Eaton · STEPEMS2-DO-T-3-SWD — DOL starter, 24 V DC, 0,18 - 3 A, Push in terminals, SmartWire-DT slaveEaton · STEPEMS2-DO-T-9-SWD — DOL starter, 24 V DC, 1,5 - 7 (AC-53a), 9 (AC-51) A, Push in terminals, SmartWire-DT slaveEaton · STEPEMS2-DOS-T-3-SWD — DOL starter, 24 V DC, 0,18 - 3 A, Push in terminals, SmartWire-DT slave, Controlled stop, PTB 19 ATEX 3000Eaton · STEPEMS2-DOS-T-9-SWD — DOL starter, 24 V DC, 1,5 - 7 (AC-53a), 9 (AC-51) A, Push in terminals, SmartWire-DT slave, Controlled stop, PTB 19 ATEX 3000Eaton · STEPEMS2-RO-T-3-SWD — Reversing starter, 24 V DC, 0,18 - 3 A, Push in terminals, SmartWire-DT slaveEaton · STEPEMS2-RO-T-9-SWD — Reversing starter, 24 V DC, 1,5 - 7 (AC-53a), 9 (AC-51) A, Push in terminals, SmartWire-DT slaveEaton · STEPEMS2-ROS-T-3-SWD — Reversing starter, 24 V DC, 0,18 - 3 A, Push in terminals, SmartWire-DT slave, Controlled stop, PTB 19 ATEX 3000Eaton · STEPEMS2-ROS-T-9-SWD — Reversing starter, 24 V DC, 1,5 - 7 (AC-53a), 9 (AC-51) A, Push in terminals, SmartWire-DT slave, Controlled stop, PTB 19 ATEX 3000Eaton · STEPEMS2-ROSF-Z-3-24VDC — Reversing starter, 24 V DC, 0,18 - 3 A, Screw terminals, Controlled stop, PTB 19 ATEX 3000Eaton · STEPEMS2-ROSF-Z-9-24VDC — Reversing starter, 24 V DC, 1,5 - 7 (AC-53a), 9 (AC-51) A, Screw terminals, Controlled stop, PTB 19 ATEX 3000Eaton · STEPHIS-20/1 — Main load disconnector Switch with isolation function, highly wear resistant contacts, 240 V, 20 A, 1PEaton · STEPHIS-20/2 — Main load disconnector Switch with isolation function, highly wear resistant contacts, 415 V, 20 A, 2PEaton · STEPHIS-20/3 — Main load disconnector Switch with isolation function, highly wear resistant contacts, 240/415 V, 20 A, 3PEaton · STEPHIS-20/4 — Main load disconnector Switch with isolation function, highly wear resistant contacts, 240/415 V, 20 A, 4PEaton · STEPHIS-25/1 — Main load disconnector Switch with isolation function, highly wear resistant contacts, 240 V, 25 A, 1PEaton · STEPHIS-25/2 — Main load disconnector Switch with isolation function, highly wear resistant contacts, 415 V, 25 A, 2PEaton · STEPHIS-25/3 — Main load disconnector Switch with isolation function, highly wear resistant contacts, 240/415 V, 25 A, 3PEaton · STEPHIS-25/4 — Main load disconnector Switch with isolation function, highly wear resistant contacts, 240/415 V, 25 A, 4PEaton · STEPHIS-32/1 — Main load disconnector Switch with isolation function, highly wear resistant contacts, 240 V, 32 A, 1PEaton · STEPHIS-32/2 — Main load disconnector Switch with isolation function, highly wear resistant contacts, 415 V, 32 A, 2PEaton · STEPHIS-32/3 — Main load disconnector Switch with isolation function, highly wear resistant contacts, 240/415 V, 32 A, 3PEaton · STEPHIS-32/4 — Main load disconnector Switch with isolation function, highly wear resistant contacts, 240/415 V, 32 A, 4PEaton · STEPHIS-40/1 — Main load disconnector Switch with isolation function, highly wear resistant contacts, 240 V, 40 A, 1PEaton · STEPHIS-40/2 — Main load disconnector Switch with isolation function, highly wear resistant contacts, 415 V, 40 A, 2PEaton · STEPHIS-40/3 — Main load disconnector Switch with isolation function, highly wear resistant contacts, 240/415 V, 40 A, 3pEaton · STEPHIS-40/4 — Main load disconnector Switch with isolation function, highly wear resistant contacts, 240/415 V, 40 A, 4PEaton · STEPHIS-63/1 — Main load disconnector Switch with isolation function, highly wear resistant contacts, 240 V, 63 A, 1PEaton · STEPHIS-63/2 — Main load disconnector Switch with isolation function, highly wear resistant contacts, 415 V, 63 A, 2PEaton · STEPHIS-63/3 — Main load disconnector Switch with isolation function, highly wear resistant contacts, 240/415 V, 63 A, 3PEaton · STEPHIS-63/4 — Main load disconnector Switch with isolation function, highly wear resistant contacts, 240/415 V, 63 A, 4PEaton · STEPHIS-80/1 — Main load disconnector Switch with isolation function, highly wear resistant contacts, 240 V, 80 A, 1PEaton · STEPHIS-80/2 — Main load disconnector Switch with isolation function, highly wear resistant contacts, 415 V, 80 A, 2PEaton · STEPHIS-80/3 — Main load disconnector Switch with isolation function, highly wear resistant contacts, 240/415 V, 80 A, 3PEaton · STEPHIS-80/4 — Main load disconnector Switch with isolation function, highly wear resistant contacts, 240/415 V, 80 A, 4PEaton · STEPHIS-100/1 — Main load disconnector Switch with isolation function, highly wear resistant contacts, 240 V, 100 A, 1PEaton · STEPHIS-100/2 — Main load disconnector Switch with isolation function, highly wear resistant contacts, 415 V, 100 A, 2PEaton · STEPHIS-100/3 — Main load disconnector Switch with isolation function, highly wear resistant contacts, 240/415 V, 100 A, 3PEaton · STEPHIS-100/4 — Main load disconnector Switch with isolation function, highly wear resistant contacts, 240/415 V, 100 A, 4PEaton · STEPHIS-125/1 — Main load disconnector Switch with isolation function, highly wear resistant contacts, 240 V, 125 A, 1PEaton · STEPHIS-125/2 — Main load disconnector Switch with isolation function, highly wear resistant contacts, 415 V, 125 A, 2PEaton · STEPHIS-125/3 — Main load disconnector Switch with isolation function, highly wear resistant contacts, 240/415 V, 125 A, 3PEaton · STEPHIS-125/4 — Main load disconnector Switch with isolation function, highly wear resistant contacts, 240/415 V, 125 A, 4PEaton · STEPIS-16/1 — Main load disconnector Switch with isolation function, highly wear resistant contacts and classified for the use in rail rolling stock, 240 V, 16 A, 1PEaton · DWG / STEPIS-16/2 — Main load disconnector Switch with isolation function, highly wear resistant contacts and classified for the use in rail rolling stock, 415 V, 16 A, 2PEaton · DWG / STEPIS-16/3 — Main load disconnector Switch with isolation function, highly wear resistant contacts and classified for the use in rail rolling stock, 240/415 V, 16 A, 3PEaton · DWG / STEPIS-16/4 — Main load disconnector Switch with isolation function, highly wear resistant contacts and classified for the use in rail rolling stock, 240/415 V, 16 A, 4PEaton · DWG / STEPIS-20/1 — Main load disconnector Switch with isolation function, highly wear resistant contacts and classified for the use in rail rolling stock, 240 V, 20 A, 1PEaton · DWG / STEPIS-20/2 — Main load disconnector Switch with isolation function, highly wear resistant contacts and classified for the use in rail rolling stock, 415 V, 20 A, 2PEaton · DWG / STEPIS-20/3 — Main load disconnector Switch with isolation function, highly wear resistant contacts and classified for the use in rail rolling stock, 240/415 V, 20 A, 3PEaton · DWG / STEPIS-20/4 — Main load disconnector Switch with isolation function, highly wear resistant contacts and classified for the use in rail rolling stock, 240/415 V, 20 A, 4PEaton · DWG / STEPIS-25/1 — Main load disconnector Switch with isolation function, highly wear resistant contacts and classified for the use in rail rolling stock, 240 V, 25 A, 1PEaton · DWG / STEPIS-25/2 — Main load disconnector Switch with isolation function, highly wear resistant contacts and classified for the use in rail rolling stock, 415 V, 25 A, 2PEaton · DWG / STEPIS-25/3 — Main load disconnector Switch with isolation function, highly wear resistant contacts and classified for the use in rail rolling stock, 240/415 V, 25 A, 3PEaton · DWG / STEPIS-25/4 — Main load disconnector Switch with isolation function, highly wear resistant contacts and classified for the use in rail rolling stock, 240/415 V, 25 A, 4PEaton · DWG / STEPIS-32/1 — Main load disconnector Switch with isolation function, highly wear resistant contacts and classified for the use in rail rolling stock, 240 V, 32 A, 1PEaton · DWG / STEPIS-32/2 — Main load disconnector Switch with isolation function, highly wear resistant contacts and classified for the use in rail rolling stock, 415 V, 32 A, 2PEaton · DWG / STEPIS-32/3 — Main load disconnector Switch with isolation function, highly wear resistant contacts and classified for the use in rail rolling stock, 240/415 V, 32 A, 3PEaton · DWG / STEPIS-32/4 — Main load disconnector Switch with isolation function, highly wear resistant contacts and classified for the use in rail rolling stock, 240/415 V, 32 A, 4PEaton · DWG / STEPIS-40/1 — Main load disconnector Switch with isolation function, highly wear resistant contacts and classified for the use in rail rolling stock, 240 V, 40 A, 1PEaton · DWG / STEPIS-40/2 — Main load disconnector Switch with isolation function, highly wear resistant contacts and classified for the use in rail rolling stock, 415 V 40 A, 2PEaton · DWG / STEPIS-40/3 — Main load disconnector Switch with isolation function, highly wear resistant contacts and classified for the use in rail rolling stock, 240/415 V, 40 A, 3PEaton · DWG / STEPIS-40/4 — Main load disconnector Switch with isolation function, highly wear resistant contacts and classified for the use in rail rolling stock, 240/415 V, 40 A, 4PEaton · DWG / STEPIS-63/1 — Main load disconnector Switch with isolation function, highly wear resistant contacts and classified for the use in rail rolling stock, 240 V, 63 A, 1PEaton · DWG / STEPIS-63/2 — Main load disconnector Switch with isolation function, highly wear resistant contacts and classified for the use in rail rolling stock, 415 V, 63 A, 2PEaton · DWG / STEPIS-63/3 — Main load disconnector Switch with isolation function, highly wear resistant contacts and classified for the use in rail rolling stock, 240/415 V, 63 A, 3PEaton · DWG / STEPIS-63/4 — Main load disconnector Switch with isolation function, highly wear resistant contacts and classified for the use in rail rolling stock, 240/415 V, 63 A, 4PEaton · DWG / STEPIS-80/1 — Main load disconnector Switch with isolation function, highly wear resistant contacts and classified for the use in rail rolling stock, 240 V, 80 A, 1PEaton · DWG / STEP

Wiring & terminals by manufacturer

Weidmüller (8,934) · Eaton (3,713) · Schneider Electric (1,944) · ABB (664) · LOVATO Electric (462) · Allen-Bradley (220) · AutomationDirect (192) · NHP (52) · nVent ERIFLEX (35) · Schrack (28) · Steute (10) · Terasaki (10) · Schweitzer Engineering Laboratories (4) · Socomec (1)

Design in 2D and 3D with AI

Design in 2D and 3D with AI

  • Create 2D and 3D from a description
  • Edit in plain words
  • Add equipment from this library
Try it on my own project

Elora Grid · AI design

Design in 2D and 3D with AI

Describe your electrical project. Create a 3D layout and 2D general arrangement.

“Create an electrical equipment layout with a switchboard, a generator and space for access.”
Design my project

Elora Grid · AI design

Design in 2D and 3D with AI

Describe your electrical project. Create a 3D layout and 2D general arrangement.

Design my project
Illustrative 3D model and matching 2D general arrangement: example electrical control panel
Illustrative category example

Elora Grid · AI design

Design in 2D and 3D with AI

Describe your electrical project. Create a 3D layout and 2D general arrangement.

Design my project
Illustrative 3D model and matching 2D general arrangement: example electrical control panel
Illustrative category example

Elora Grid · AI design

Design in 2D and 3D with AI

Describe your electrical project. Create a 3D layout and 2D general arrangement.

Design my project
Illustrative 3D model: example electrical control panel
Illustrative category example

Elora Grid · AI design

Save hours per week on electrical design and drawings with AI

Describe your electrical project. Create a 3D layout and 2D general arrangement.

Design my project
Illustrative 3D model and matching 2D general arrangement: example electrical control panel
Illustrative category example