LAPP Insulators

318461-70 porcelain station-post insulator dimensions & PDF reference

318461-70 porcelain station-post insulator from LAPP Insulators. The manufacturer table lists Leakage Distance, Reference Standard, in. [mm]: 72 [1829]; Leakage Distance, High Leak, in. [mm]: 102 [2591]; Cantilever Strength, lbs. [kN]: 6000 [26.7]. Download the source catalogue and inspect the 318461-70 column.

PDF · 1 listed file · Source checked 2026-11-03

Download files

Original files · Hosted here

250-350kV

PDF · 309 KB · Reference document

Original filename: 250-350kV.pdf

Manufacturer catalogue with 318461-70 data and outline references on PDF page 2

Need another model or format?

Request manufacturer CAD

318461-70 porcelain station-post insulator

Enter your email and our team can request the manufacturer's drawings for this equipment.

Sent to our team for manufacturer follow-up. Availability and timing will be confirmed by email. Privacy policy

Equipment and file summary

Equipment / resource
318461-70 porcelain station-post insulator
Manufacturer
LAPP Insulators
Resource type
Product
Part number
318461-70
Leakage Distance, Reference Standard, in. [mm]
72 [1829]
Leakage Distance, High Leak, in. [mm]
102 [2591]
Cantilever Strength, lbs. [kN]
6000 [26.7]
Tensile Strength, lbs. [kN]
40000 [177.9]
Compression Strength, lbs. [kN]
120000 [533.6]
Impulse Withstand, kV
350
Net Weight, Each, lbs. [kg]
184.5 [83.7]
Listed file formats
PDF
Listed files
1
Available previews
1 catalogue page previews
Recorded revisions
Confirm the revision with the manufacturer
Source checked
2026-11-03
Download access
Email registration for site downloads; official source links are also available

Catalogue preview

Manufacturer catalogue page 2; use the table column for the exact model named on this page
250-350kV · page 2: CAD drawing preview
Zoom 100%
Download original drawing ↓

Explore the model in 3D

You can preview the supplied 2D drawings here. Use the original file links above or request a matching model for your exact configuration.

Request manufacturer CAD

318461-70 porcelain station-post insulator

Enter your email and our team can request the manufacturer's drawings for this equipment.

Sent to our team for manufacturer follow-up. Availability and timing will be confirmed by email. Privacy policy

Which file should I choose?

Download 250-350kV.pdf and open PDF page 2. Find the 318461-70 column; other tables and model rows or columns describe different insulators. This source is a catalogue PDF. A native DWG or STEP file is not included; use Request CAD for an editable model.

What is included?

318461-70 porcelain station-post insulator lists 1 file route from LAPP Insulators. Drawing content: porcelain station-post insulator, manufacturer model-specific table, catalogue outline reference.

Checked source file: 250-350kV.pdf · 309 KB · PDF.

Before using it

  • For 318461-70, the source records Leakage Distance, Reference Standard, in. [mm]: 72 [1829]. Match that value to the conductor-support arrangement.
  • Compare the 318461-70 column on PDF page 2 with the exact fixing or stud arrangement shown in the catalogue; use the dimensions for this exact reference.
  • The source also lists Leakage Distance, High Leak, in. [mm]: 102 [2591]. Check the project requirement against the manufacturer’s specified units and conditions.
  • Leakage distance follows the insulating surface. It is different from the overall height; use the height value for the physical layout.

In plain English

What the equipment does

A station-post insulator supports an energised conductor while separating it electrically from its grounded support. Its end fittings, height and mechanical strength determine how it can be mounted.

A simple example

When positioning 318461-70 on a substation support, use PDF page 2 to compare its mounting interfaces with the structure and conductor connection. The listed Leakage Distance, Reference Standard, in. [mm] is 72 [1829].

Questions about this resource

Where is the 318461-70 information in this download?

Open PDF page 2 of 250-350kV.pdf and find the 318461-70 column. The page preview preserves the manufacturer table; the download contains the complete catalogue.

Is an editable CAD model included for 318461-70?

This entry provides the manufacturer PDF reference and its model-specific values. A DWG, DXF or STEP model is not attached; request the exact model and preferred format here.

Equipment references and drawing guides

Related GA equipment

Electrical drawing guides →

Use in a project

Sources & versions

Original publisher: LAPP Insulators. Source checked 2026-11-03. Original bytes are preserved; file links and document references identify the source.

Manufacturer
LAPP Insulators
Resource
Product · 318461-70
Formats
PDF
Regional source coverage
Global

The source table supplies the listed product values. The project insulation, mechanical loading and regional requirements must be checked for the selected installation.

Verified file identity

250-350kV.pdf · PDF · 316,675 bytes

SHA-256: 5a231bb9db44ab35d20fb942e249c9598dc52c313bf3c9c94bf751fdbda694c0

More switchboards & switchgear · More LAPP Insulators drawings · Request other equipment