PPC Insulators

C4-170 IEC porcelain station-post insulator dimensions & PDF reference

C4-170 station-post insulator from PPC Insulators. The manufacturer table lists Height H [mm]: 445 ± 1; Max. nom. diameter of insulating part d1 [mm]: 180; Minimum failing load - Bending [kN]: 4. Download the source catalogue and inspect the C4-170 column.

PDF · 1 listed file · Source checked 2026-11-03

Download files

Original files · Hosted here

PPC IEC Solid-Core A4 LQ

PDF · 2.0 MB · Reference document

Original filename: PPC_IEC_Solid-Core_A4_LQ.pdf

Manufacturer catalogue with C4-170 data and outline references on PDF page 22, 23

Need another model or format?

Request manufacturer CAD

C4-170 IEC porcelain station-post insulator

Enter your email and our team can request the manufacturer's drawings for this equipment.

Sent to our team for manufacturer follow-up. Availability and timing will be confirmed by email. Privacy policy

Equipment and file summary

Equipment / resource
C4-170 IEC porcelain station-post insulator
Manufacturer
PPC Insulators
Resource type
Product
Part number
C4-170
Height H [mm]
445 ± 1
Max. nom. diameter of insulating part d1 [mm]
180
Minimum failing load - Bending [kN]
4
Lightning impulse withstand voltage, dry [kV peak value]
170
Power frequency withstand voltage, wet [kV r.m.s.]
70
Listed file formats
PDF
Listed files
1
Available previews
2 catalogue page previews
Recorded revisions
Confirm the revision with the manufacturer
Source checked
2026-11-03
Download access
Email registration for site downloads; official source links are also available

Catalogue preview

Manufacturer catalogue page 22; use the table column for the exact model named on this page
PPC IEC Porcelain Solid Core Station Post Insulators · page 22: CAD drawing preview
Zoom 100%
Download original drawing ↓

Explore the model in 3D

You can preview the supplied 2D drawings here. Use the original file links above or request a matching model for your exact configuration.

Request manufacturer CAD

C4-170 IEC porcelain station-post insulator

Enter your email and our team can request the manufacturer's drawings for this equipment.

Sent to our team for manufacturer follow-up. Availability and timing will be confirmed by email. Privacy policy

Which file should I choose?

Download PPC_IEC_Solid-Core_A4_LQ.pdf and open PDF page 22. Find the C4-170 column; other tables and model rows or columns describe different insulators. The following preview page contains the associated outline diagrams. This source is a catalogue PDF. A native DWG or STEP file is not included; use Request CAD for an editable model.

What is included?

C4-170 IEC porcelain station-post insulator lists 1 file route from PPC Insulators. Drawing content: station-post insulator, manufacturer model-specific table, catalogue outline reference.

Checked source file: PPC_IEC_Solid-Core_A4_LQ.pdf · 2.0 MB · PDF.

Before using it

  • For C4-170, the source records Height H [mm]: 445 ± 1. Match that value to the conductor-support arrangement.
  • Compare the C4-170 column on PDF page 22 with the exact fixing or stud arrangement shown in the catalogue; use the dimensions for this exact reference.
  • The source also lists Max. nom. diameter of insulating part d1 [mm]: 180. Check the project requirement against the manufacturer’s specified units and conditions.
  • BIL or impulse withstand describes a short impulse test value. It is not the continuous operating-voltage rating.

In plain English

What the equipment does

A station-post insulator supports an energised conductor while separating it electrically from its grounded support. Its end fittings, height and mechanical strength determine how it can be mounted.

A simple example

When positioning C4-170 on a substation support, use PDF page 22 to compare its mounting interfaces with the structure and conductor connection. The listed Height H [mm] is 445 ± 1.

Questions about this resource

Where is the C4-170 information in this download?

Open PDF page 22 of PPC_IEC_Solid-Core_A4_LQ.pdf and find the C4-170 column. The page preview preserves the manufacturer table; the download contains the complete catalogue.

Is an editable CAD model included for C4-170?

This entry provides the manufacturer PDF reference and its model-specific values. A DWG, DXF or STEP model is not attached; request the exact model and preferred format here.

Equipment references and drawing guides

Related GA equipment

Electrical drawing guides →

Use in a project

Sources & versions

Original publisher: PPC Insulators. Source checked 2026-11-03. Original bytes are preserved; file links and document references identify the source.

Manufacturer
PPC Insulators
Resource
Product · C4-170
Formats
PDF
Regional source coverage
Global

The source table supplies the listed product values. The project insulation, mechanical loading and regional requirements must be checked for the selected installation.

Verified file identity

PPC_IEC_Solid-Core_A4_LQ.pdf · PDF · 2,087,364 bytes

SHA-256: 506a8514c890a941a0070b83a7d41fc8b5c10217be71bda6fc66ff1bcfe9f40f

More switchboards & switchgear · More PPC Insulators drawings · Request other equipment