Victor Insulators

1766 porcelain station-post insulator dimensions & PDF reference

1766 porcelain station-post insulator from Victor Insulators. The manufacturer table lists Height (in.): 10; ANSI TR reference: 222 225; Voltage rating (kV): 7.5. Download the source catalogue and inspect the row for 1766.

PDF · 1 listed file · Source checked 2026-11-03

Download files

Original files · Hosted here

Victor-Insulators-2026-Catalog full-Substation

PDF · 14.0 MB · Reference document

Original filename: Victor-Insulators-2026-Catalog_full-Substation.pdf

Manufacturer catalogue with 1766 data and outline references on PDF page 8

Need another model or format?

Request manufacturer CAD

1766 porcelain station-post insulator

Enter your email and our team can request the manufacturer's drawings for this equipment.

Sent to our team for manufacturer follow-up. Availability and timing will be confirmed by email. Privacy policy

Equipment and file summary

Equipment / resource
1766 porcelain station-post insulator
Manufacturer
Victor Insulators
Resource type
Product
Part number
1766
Height (in.)
10
ANSI TR reference
222 225
Voltage rating (kV)
7.5
BIL (kV)
95
Cantilever strength (lb)
4000 4000
Import alternative
1766I
Listed file formats
PDF
Listed files
1
Available previews
1 catalogue page previews
Recorded revisions
Confirm the revision with the manufacturer
Source checked
2026-11-03
Download access
Email registration for site downloads; official source links are also available

Catalogue preview

Manufacturer catalogue page 8; use the table column for the exact model named on this page
Substation · page 8: CAD drawing preview
Zoom 100%
Download original drawing ↓

Explore the model in 3D

You can preview the supplied 2D drawings here. Use the original file links above or request a matching model for your exact configuration.

Request manufacturer CAD

1766 porcelain station-post insulator

Enter your email and our team can request the manufacturer's drawings for this equipment.

Sent to our team for manufacturer follow-up. Availability and timing will be confirmed by email. Privacy policy

Which file should I choose?

Download Victor-Insulators-2026-Catalog_full-Substation.pdf and open PDF page 8. Find the row for 1766; other tables and model rows or columns describe different insulators. This source is a catalogue PDF. A native DWG or STEP file is not included; use Request CAD for an editable model.

What is included?

1766 porcelain station-post insulator lists 1 file route from Victor Insulators. Drawing content: porcelain station-post insulator, manufacturer model-specific table, catalogue outline reference.

Checked source file: Victor-Insulators-2026-Catalog_full-Substation.pdf · 14.0 MB · PDF.

Before using it

  • For 1766, the source records Height (in.): 10. Match that value to the conductor-support arrangement.
  • Compare the row for 1766 on PDF page 8 with the exact fixing or stud arrangement shown in the catalogue; use the dimensions for this exact reference.
  • The source also lists ANSI TR reference: 222 225. Check the project requirement against the manufacturer’s specified units and conditions.
  • BIL or impulse withstand describes a short impulse test value. It is not the continuous operating-voltage rating.

In plain English

What the equipment does

A station-post insulator supports an energised conductor while separating it electrically from its grounded support. Its end fittings, height and mechanical strength determine how it can be mounted.

A simple example

When positioning 1766 on a substation support, use PDF page 8 to compare its mounting interfaces with the structure and conductor connection. The listed Height (in.) is 10.

Questions about this resource

Where is the 1766 information in this download?

Open PDF page 8 of Victor-Insulators-2026-Catalog_full-Substation.pdf and find the row for 1766. The page preview preserves the manufacturer table; the download contains the complete catalogue.

Is an editable CAD model included for 1766?

This entry provides the manufacturer PDF reference and its model-specific values. A DWG, DXF or STEP model is not attached; request the exact model and preferred format here.

Equipment references and drawing guides

Related GA equipment

Electrical drawing guides →

Use in a project

Sources & versions

Original publisher: Victor Insulators. Source checked 2026-11-03. Original bytes are preserved; file links and document references identify the source.

Manufacturer
Victor Insulators
Resource
Product · 1766
Formats
PDF
Regional source coverage
Global

The source table supplies the listed product values. The project insulation, mechanical loading and regional requirements must be checked for the selected installation.

Verified file identity

Victor-Insulators-2026-Catalog_full-Substation.pdf · PDF · 14,636,783 bytes

SHA-256: cd4b2c7e19718be233ee6820589e786bc30f6f80eaff72afd5889943d3fad5ec

More switchboards & switchgear · More Victor Insulators drawings · Request other equipment