Datasheet

Product code
112-32-3311
Rated voltage
600/1000 V
Conductor
1 × 4 AWG Copper
Insulation
XLPE
Conductor construction
7 strand(s)
Outside diameter
0.34 in
p. 1p. 2

Using this cable in a drawing

Use the published approximate outside diameter of 0.34 in for the cable outline. The drawing shows a straight, illustrative run of 4.08 in. Supports, terminations and installation clearances are project-specific. p. 2

Published current rating. 95 A · ambient 30 °C · conductor temperature 90 °C · NEC wet column per manufacturer footnote (1); see small-conductor overcurrent limitations. p. 2

Download arrangement DXF · Symbol DXF · Editable 3D envelope

Compare a nearby size

X-Olene · Copper · 600/1000 V. Both columns use the publisher’s original units.

Parameter4 AWG · 112-32-33112 AWG · 112-32-3371
Overall diameter0.34 in0.4 in
Cable weight151 lb/1000 ft231 lb/1000 ft
Current ratingambient 30 °C · conductor temperature 90 °C · NEC wet column per manufacturer footnote (1); see small-conductor overcurrent limitations95 A130 A
Current ratingambient 30 °C · conductor temperature 75 °C · NEC wet column per manufacturer footnote (1); see small-conductor overcurrent limitations85 A115 A

Calculation parameters and conditions

ParameterValueManufacturer basisSource
Overall diameter0.34 inApproximatep. 2
Cable weight151 lb/1000 ftApproximate net weightp. 2
Operating temperature90 °CWet or dryp. 1
Current rating95 Aambient 30 °C · conductor temperature 90 °C · NEC wet column per manufacturer footnote (1); see small-conductor overcurrent limitationsp. 2
Current rating85 Aambient 30 °C · conductor temperature 75 °C · NEC wet column per manufacturer footnote (1); see small-conductor overcurrent limitationsp. 2

Source and files

Okonite sheet 3-4 · X-Olene Type RHH or RHW-2, 600V/1000V Power and Control Cable, Copper Conductor · J/26020304. Retrieved 2026-11-19.

Open manufacturer PDF · Search this PDF · Download datasheet PDF · Download typed JSON

SHA-256 5e55daabff8df4efacfabf9f057c5ce213f85263cc93d34386ff960fd59c6125
Design in 2D and 3D with AI

Design in 2D and 3D with AI

  • Create 2D and 3D from a description
  • Edit in plain words
  • Add equipment from this library
Try it on my own project

Elora Grid · AI design

Design in 2D and 3D with AI

Describe your electrical project. Create a 3D layout and 2D general arrangement.

Design my project

Elora Grid · AI design

Design in 2D and 3D with AI

Describe your electrical project. Create a 3D layout and 2D general arrangement.

“Create an electrical equipment layout with a switchboard, a generator and space for access.”
Design my project

Elora Grid · AI design

Design in 2D and 3D with AI

Describe your electrical project. Create a 3D layout and 2D general arrangement.

Design my project
3D electrical equipment layout