RHH/RHW-2 · 250 kcmil 112-32-3511
X-Olene · 600/1000 V · 1-core copper

Datasheet
- Product code
- 112-32-3511
- Rated voltage
- 600/1000 V
- Conductor
- 1 × 250 kcmil Copper
- Insulation
- XLPE
- Conductor construction
- 37 strand(s)
- Outside diameter
- 0.73 in
Using this cable in a drawing
Use the published approximate outside diameter of 0.73 in for the cable outline. The drawing shows a straight, illustrative run of 8.76 in. Supports, terminations and installation clearances are project-specific. p. 2
Published current rating. 290 A · ambient 30 °C · conductor temperature 90 °C · NEC wet column per manufacturer footnote (1); see small-conductor overcurrent limitations. p. 2
Download arrangement DXF · Symbol DXF · Editable 3D envelope
Compare a nearby size
X-Olene · Copper · 600/1000 V. Both columns use the publisher’s original units.
| Parameter | 250 kcmil · 112-32-3511 | 300 kcmil · 112-32-3521 |
|---|---|---|
| Overall diameter | 0.73 in | 0.78 in |
| Cable weight | 843 lb/1000 ft | 1002 lb/1000 ft |
| Current ratingambient 30 °C · conductor temperature 90 °C · NEC wet column per manufacturer footnote (1); see small-conductor overcurrent limitations | 290 A | 320 A |
| Current ratingambient 30 °C · conductor temperature 75 °C · NEC wet column per manufacturer footnote (1); see small-conductor overcurrent limitations | 255 A | 285 A |
Calculation parameters and conditions
| Parameter | Value | Manufacturer basis | Source |
|---|---|---|---|
| Overall diameter | 0.73 in | Approximate | p. 2 |
| Cable weight | 843 lb/1000 ft | Approximate net weight | p. 2 |
| Operating temperature | 90 °C | Wet or dry | p. 1 |
| Current rating | 290 A | ambient 30 °C · conductor temperature 90 °C · NEC wet column per manufacturer footnote (1); see small-conductor overcurrent limitations | p. 2 |
| Current rating | 255 A | ambient 30 °C · conductor temperature 75 °C · NEC wet column per manufacturer footnote (1); see small-conductor overcurrent limitations | p. 2 |
Source and files
Okonite sheet 3-4 · X-Olene Type RHH or RHW-2, 600V/1000V Power and Control Cable, Copper Conductor · J/26020304. Retrieved 2026-11-19.
Open manufacturer PDF · Search this PDF · Download datasheet PDF · Download typed JSON
SHA-256 5e55daabff8df4efacfabf9f057c5ce213f85263cc93d34386ff960fd59c6125Design in 2D and 3D with AI
- Create 2D and 3D from a description
- Edit in plain words
- Add equipment from this library
Elora Grid · AI design
Design in 2D and 3D with AI
Describe your electrical project. Create a 3D layout and 2D general arrangement.
Elora Grid · AI design
Design in 2D and 3D with AI
Describe your electrical project. Create a 3D layout and 2D general arrangement.
“Create an electrical equipment layout with a switchboard, a generator and space for access.”Design my project
Elora Grid · AI design
Design in 2D and 3D with AI
Describe your electrical project. Create a 3D layout and 2D general arrangement.