Functional block · MSCLI

Microgrid storage charge-power limit interface

Functional block · Microgrids

An independently authored application reference. The drawing shows the named function or circuit relationship; use the project legend and selected equipment documentation for its drafting form and connections.

Browse this installation focus

In plain English

What this block does

Receives the declared maximum permitted charging power for the assigned storage resource.

A simple example

In a microgrid with a battery energy storage system, the controller can request discharge to support a power deficit while the battery management and conversion systems enforce their own operating limits. For this reference, the drawing identifies “Storage charge limit” at the input and “Permitted charge capability” at the output. The limit can change with battery and converter conditions.

Storage charge limitMSCLIPermitted charge capability
A reading guide. The entry's original illustration and input/output facts describe this application.

What the drawings help you do

Start at the named input: Storage charge limit. Identify its source device or document and the state represented on the drawing. Follow the named output: Permitted charge capability. Cross-reference its destination and separate the command from confirmation that the equipment responded.

Input
Storage charge limit
Output
Permitted charge capability
Application reference
An explanation of a named drawing function or circuit relationship; the project documents define the equipment and its connections.

Read the source: Avista Shared Energy Economy microgrid protection and control case study

Schematic · MSCLIMicrogrid storage charge-power limit interface: original educational illustration
Original educational illustrationSee source and graphic notes

What it represents

Receives the declared maximum permitted charging power for the assigned storage resource. Storage coordination combines the battery's energy limits with the converter's electrical capability and the microgrid's operating demand. State of charge, allowable power and connection status describe different aspects of availability.

In a microgrid with a battery energy storage system, the controller can request discharge to support a power deficit while the battery management and conversion systems enforce their own operating limits. For this reference, the drawing identifies “Storage charge limit” at the input and “Permitted charge capability” at the output. The limit can change with battery and converter conditions.

Show which system declares each limit and which controller receives the target. Battery protection, converter capability, thermal management and emergency responses remain with the selected system design. The functional block is an independent explanation of this named application. Equipment-specific ratings, terminal connections and operating conditions must be established in the project documentation.

How to read it

  • Start at the named input: Storage charge limit. Identify its source device or document and the state represented on the drawing.
  • Follow the named output: Permitted charge capability. Cross-reference its destination and separate the command from confirmation that the equipment responded.
  • The limit can change with battery and converter conditions.
  • Show which system declares each limit and which controller receives the target. Battery protection, converter capability, thermal management and emergency responses remain with the selected system design.

Information to show or reference

  • Label the source and connection reference for storage charge limit.
  • Identify the destination and defined state of permitted charge capability.
  • Record the equipment or control-document revision supporting this functional block.
  • Check this application limit in the project design: The limit can change with battery and converter conditions.

A distinction that matters

The limit can change with battery and converter conditions. This reference describes the named application; it does not establish a new IEC graphical symbol, an ANSI device-function number or an exact manufacturer connection diagram.

Sources you can follow

These public references support the explanation and provide further detail. Their graphics and downloadable files remain with their publishers.

Avista Shared Energy Economy microgrid protection and control case study

Public technical context for microgrid storage coordination interfaces. Storage, protection, black start, load restoration and coordinated island operation. The application text and educational graphic are independently authored; the publisher does not certify this representation.

SEL · Public reference checked 3 November 2026 · Link only

About this graphic

This illustration was authored independently by Elora Grid to explain the concept. It is not reproduced from a customer drawing, an official standard graphic or a manufacturer CAD file. Its correspondence to an exact IEC or IEEE symbol identifier has not been certified.

SVG and DXF downloads contain this original artwork. Original artwork is available under CC BY 4.0. Third-party references retain their own terms.

Entry JSON · Entry Markdown · Last editorial update: 3 November 2026

Put the reference into a drawing workflow.

Elora Grid helps electrical teams work with drawings, specifications and equipment information. Explore the drafting workflow or join the early-access waitlist.

Explore drafting