2D STY 020: CAD drawing preview
Zoom 100%
Download original drawing ↓

BFK1210A400 — Contactor for power factor correction, limiting resistors included, BFK12 10 A400, 12,5kvar (400VAC)

LOVATO Electric logo
Equipment / resource
BFK1210A400 — Contactor for power factor correction, limiting resistors included, BFK12 10 A400, 12,5kvar (400VAC)
Manufacturer
LOVATO Electric
Resource type
Product
Part number
BFK1210A400
Manufacturer reference
BFK1210A400
Available native formats
DWG / DXF / STEP

Downloads & Requests

Download ZIP

No Elora account or email required. Manufacturer access requirements may apply.

Choose multiple files or formats

Public files download without signup. Only exclusive Elora conversions need a free account.

Select files

Request CAD

Equipment & documents

BFK1210A400 — Contactor for power factor correction, limiting resistors included, BFK12 10 A400, 12,5kvar (400VAC)

Choose documents & file formats (optional)

Which documents do you need? (optional)
Preferred file formats (optional)

Choose what works with your software. These are request preferences; the team will confirm what the manufacturer supplies.

Project details Optional · helps us request the right variant

Where should we follow up?

Our team can contact manufacturers on your behalf and follow up by email. Contact details are used for this request. Privacy policy · Contact the team

About this equipment

What it does

LOVATO Electric BFK1210A400 — Contactor for power factor correction, limiting resistors included, BFK12 10 A400, 12,5kvar (400VAC). Retained manufacturer CAD files and drawings for automation design and equipment layout.

In plain English

A power-factor-correction capacitor bank supplies reactive power locally so the installation draws less reactive power from its incoming supply.

Design in 2D and 3D with AI

Design in 2D and 3D with AI

  • Create 2D and 3D from a description
  • Edit in plain words
  • Add equipment from this library
Try it on my own project

Elora Grid · AI design

Lay out your control panel with AI

Turn your panel description into a 3D layout and 2D general arrangement.

Design a control panel

Elora Grid · AI design

Lay out your control panel with AI

Turn your panel description into a 3D layout and 2D general arrangement.

“Create a control-panel layout with a DIN-rail power supply, controller, terminal blocks and cable duct.”
Design a control panel

Elora Grid · AI design

Lay out your control panel with AI

Turn your panel description into a 3D layout and 2D general arrangement.

Design a control panel
3D control panel with DIN-rail equipment

Choosing and using the files

Which file should I choose?

Use 2d_BFK1210A400.dwg to insert the supplied editable drawing into your layout. The ZIP contains the unmodified 2d_BFK1210A400.dwg.

Use 3d_BFK1210A400.stp to place the original solid geometry in your 3D assembly. The ZIP contains the unmodified 3d_BFK1210A400.stp.

Use 2D_STY_020.dxf to insert the supplied editable drawing into your layout. The ZIP contains the unmodified 2D_STY_020.dxf. This is a CAD-library source view. Hide application setup dimensions and unfilled attribute templates when placing it; the original file retains these helpers.

What is included?

3 inspected originals for LOVATO Electric BFK1210A400 — Contactor for power factor correction, limiting resistors included, BFK12 10 A400, 12,5kvar (400VAC): 2d_BFK1210A400.dwg (DWG); 3d_BFK1210A400.stp (STEP); 2D_STY_020.dxf (DXF).

Before using it

  • Match LOVATO Electric BFK1210A400 and the exact source filename shown above.
  • The source was checked on 2026-11-17. Use Documentation & sources to check for a newer issue.
File details & source

2D STY 020

DXF · 64 KB

Original filename: 2D_STY_020.dxf

Manufacturer CAD-library source view; application helper dimensions and attributes remain in the unchanged native file

Questions about this resource

Which original files are supplied for BFK1210A400 — Contactor for power factor correction, limiting resistors included, BFK12 10 A400, 12,5kvar (400VAC)?

3 inspected originals for LOVATO Electric BFK1210A400 — Contactor for power factor correction, limiting resistors included, BFK12 10 A400, 12,5kvar (400VAC): 2d_BFK1210A400.dwg (DWG); 3d_BFK1210A400.stp (STEP); 2D_STY_020.dxf (DXF).

Where did these LOVATO Electric files come from?

LOVATO Electric supplied the original files through https://catalogue.lovatoelectric.com/gl_en/BFK1210A400/BFK1210A400/snp. The source reference, revision, original bytes and checksum are retained with each download.

Documentation & sources

File origin and additional details

Original publisher: LOVATO Electric. Source checked 2026-11-17. Original bytes are preserved; file links and document references identify the source.

Manufacturer
LOVATO Electric
Resource
Product · BFK1210A400
Formats
DWG / DXF / STEP
Regional source coverage
Global

Manufacturer CAD source discovery. Confirm regional equipment configuration and approvals with the manufacturer.

More automation & controls · More LOVATO Electric drawings · Request other equipment