Prysmian · Australia

3CCUX3HD · 70 mm²

Medium Voltage · 1.9/3.3 kV · 3-core copper

Illustrative 3D cable outside envelope
3D cable envelope
PlanAASection A–AOutside diameter 44.8 mm
2D general arrangement
Supply bus3-phase feeder1 × 3-core · 70 mm²
Electrical single-line representation

Datasheet

Product code
3CCUX3HD
Rated voltage
1.9/3.3 kV
Conductor
3 × 70 mm² Copper
Insulation
XLPE
Armour
Unarmoured
Construction
heavy duty screened unarmoured
Outside diameter
44.8 mm
p. 16p. 17

Using this cable in a drawing

Use the published approximate outside diameter of 44.8 mm for the cable outline. The drawing shows a straight, illustrative run of 537.6 mm. Supports, terminations and installation clearances are project-specific. p. 17

Published current rating. 240 A · Direct buried, compacted backfill · soil temperature 25 °C · soil thermal resistivity 1.2 °C·m/W · depth 0.8 m · Single three-core cable, balanced load, screens bonded at both ends · conductor temperature 90 °C. p. 17p. 131

Download arrangement DXF · Symbol DXF · Editable 3D envelope

Compare a nearby size

Medium Voltage · Copper · 1.9/3.3 kV. Both columns use the publisher’s original units.

Parameter70 mm² · 3CCUX3HD50 mm² · 3CCUX3HD
Overall diameter44.8 mm40.8 mm
Cable weight350 kg/100 m260 kg/100 m
DC resistance0.268 Ω/km0.387 Ω/km
Current ratingDirect buried, compacted backfill · soil temperature 25 °C · soil thermal resistivity 1.2 °C·m/W · depth 0.8 m · Single three-core cable, balanced load, screens bonded at both ends · conductor temperature 90 °C240 A195 A
Current ratingSingleway duct, one cable per duct · soil temperature 25 °C · soil thermal resistivity 1.2 °C·m/W · depth 0.8 m · Single three-core cable, balanced load, screens bonded at both ends · conductor temperature 90 °C205 A165 A

Calculation parameters and conditions

ParameterValueManufacturer basisSource
Overall diameter44.8 mmApproximatep. 17
Cable weight350 kg/100 mApproximate massp. 17
DC resistance0.268 Ω/kmMaximum · conductor temperature 20 °Cp. 17
Minimum bend radius810 mmDuring installation, PVCp. 17
AC resistance0.342 Ω/kmconductor temperature 90 °C · frequency 50 Hz · Three-core cablep. 17
Current rating240 ADirect buried, compacted backfill · soil temperature 25 °C · soil thermal resistivity 1.2 °C·m/W · depth 0.8 m · Single three-core cable, balanced load, screens bonded at both ends · conductor temperature 90 °Cp. 17p. 131
Current rating205 ASingleway duct, one cable per duct · soil temperature 25 °C · soil thermal resistivity 1.2 °C·m/W · depth 0.8 m · Single three-core cable, balanced load, screens bonded at both ends · conductor temperature 90 °Cp. 17p. 131

Source and files

Prysmian Medium Voltage Cables · 3CALX11HD · April 2015. Retrieved 2026-11-19.

Open manufacturer PDF · Search this PDF · Download datasheet PDF · Download typed JSON

SHA-256 4737d3bec581feeca321663725acccf526e1d307e2256e8038ebd1e0765a1a40
Design in 2D and 3D with AI

Design in 2D and 3D with AI

  • Create 2D and 3D from a description
  • Edit in plain words
  • Add equipment from this library
Try it on my own project

Elora Grid · AI design

Design in 2D and 3D with AI

Describe your electrical project. Create a 3D layout and 2D general arrangement.

Design my project

Elora Grid · AI design

Design in 2D and 3D with AI

Describe your electrical project. Create a 3D layout and 2D general arrangement.

“Create an electrical equipment layout with a switchboard, a generator and space for access.”
Design my project

Elora Grid · AI design

Design in 2D and 3D with AI

Describe your electrical project. Create a 3D layout and 2D general arrangement.

Design my project
3D electrical equipment layout