Metering & protection
Page 2 of 6 · 536 references, with definitions, drawing context and available downloads and previews.
Calculated residual instantaneous overcurrent50R · SLD / SchematicCalculated residual time-overcurrent51R · SLD / SchematicCapacitive level sensorCAP LVL · SchematicCapacitive VT carrier-coupling boundaryCVCB · SchematicCapacitor voltage transformerCVT / CCVT · SLD / SchematicChecking or interlocking relay3 · SLD / SchematicCircuit-breaker failure protection50BF · SLD / SchematicCombined instrument transformerCT/VT · SLD / SchematicCombined line and phase voltmeter selectorHSW1S92 · SchematicCombined recording wattmeter and varmeterW/var · SLD / SchematicControl power disconnecting device8 · SLD / SchematicCore-balance current transformerCBCT · SLD / SchematicCT multi-ratio tap selection referenceCMTSR · SchematicCT polarity-reference transferCPT · SchematicCT ratio-correction calculation blockCRCB · SchematicCT secondary burden allocation referenceCSBAR · SchematicCT secondary lead-resistance allowanceCSLA · SchematicCT secondary protection-zone crossoverCSPC · SchematicCT secondary shorting-test boundaryCSSB · SchematicCT secondary single-earthing-point referenceCSSR · SchematicCT secondary star-point connectionCSSC · SchematicCT secondary terminal identification boundaryCSTIB · SchematicCurrent test switch with shorting contactTS · SchematicCurrent transformerCT · SLD / SchematicCurrent transformer with primary conductor indicationCT PRI · SLD / SchematicCurrent transformer with two secondariesCT 2SEC · SLD / SchematicCurrent unbalance / negative sequence46 · SLD / SchematicCurrent window monitoring relayI WINDOW · SLD / SchematicCurrent-measurement merging-unit publisherCMP · SchematicData communications device16 · SLD / SchematicDC circuit breaker72 · SLD / SchematicDC load-measuring reclosing relay82 · SLD / SchematicDC overcurrent relay76 · SLD / SchematicDedicated bus-protection CT core interfaceDBCCI · SchematicDedicated line-protection CT core interfaceDLCCI · SchematicDedicated transformer-protection CT core interfaceDTCCI · SchematicDefinite-time delay qualifier for measuring relayst · Schematic / SLDDensity switch or sensor61 · SLD / SchematicDifferential protection87 · SLD / SchematicDifferential voltmeterDELTA V · SLD / SchematicDifferential-current measuring relayI DIFF · SLD / SchematicDigital breaker-command output boundaryDBOB · SchematicDigital secondary test-mode indicationDSTI · SchematicDigital-secondary channel identity cross-referenceDCIC · SchematicDirect transfer-trip receive interfaceDTRI · SchematicDirect transfer-trip send interfaceDTSI · SchematicDirect-operate command interfaceDCI · SchematicDirectional ground-overcurrent67G · SLD / SchematicDirectional measuring element qualifier→ · Schematic / SLDDirectional negative-sequence overcurrent67Q · SLD / SchematicDirectional neutral-overcurrent67N · SLD / SchematicDirectional overcurrent67 · SLD / SchematicDirectional phase-overcurrent67P · SLD / SchematicDirectional power32 · SLD / SchematicDirectional reactive-power protection32V · SLD / SchematicDirectional-comparison blocking interfaceDBI · SchematicDisplacement power-factor supervision55D · SLD / SchematicDistance protection21 · SLD / SchematicDisturbance recorderDFR · SLD / SchematicDouble frequency meterHz Hz · SLD / SchematicDouble voltmeterV V · SLD / SchematicEarth-fault current relayK · Schematic / SLDEarth-fault voltage relayK · Schematic / SLDElectrically operated valve20 · SLD / SchematicEnergy meter repeaterkWh · SchematicEnergy meter with maximum-demand indicatorkWh/MD · SLD / SchematicEnergy meter with pulse transmitterkWh · SLD / SchematicEnergy submeterGA · GA / SchematicEqualizer circuit breaker22 · SLD / SchematicEvent recorder time-quality flagERTF · SchematicExcess-energy meterkWh> · SLD / SchematicExciter or DC generator relay53 · SLD / SchematicFault passage indicatorFPI · SLD / SchematicField application relay56 · SLD / SchematicField circuit breaker41 · SLD / SchematicField ground-fault protection64F · SLD / SchematicField or loss-of-excitation protection40 · SLD / SchematicField-changing contactor93 · SLD / SchematicFlame detector28 · SLD / SchematicFlow switch or relay80 · SLD / SchematicFour-point current measurement selectorHSW1S95 · SchematicFrequency meterHz · SLD / SchematicFrequency monitoring relayf MON · SLD / SchematicFrequency protection81 · SLD / SchematicGalvanometerG · SchematicGenerator current-unbalance protection46G · SLD / SchematicGenerator differential protection87G · SLD / SchematicGenerator-voltage synchronising input interfaceGSII · SchematicGOOSE interlock publisher interfaceGIPI · SchematicGOOSE interlock subscriber interfaceGISI · SchematicGOOSE supervision timeout interfaceGSTI · SchematicGOOSE trip publisher interfaceGTPI · SchematicGOOSE trip subscriber interfaceGTSI · SchematicGovernor65 · SLD / SchematicGround detector protection64 · SLD / SchematicGround distance protection21G · SLD / SchematicHall-effect current sensorHALL I · SchematicImpulse tachometric transducerHIN1B12 · SchematicIncomplete-sequence relay48 · SLD / SchematicIndicating instrument general symbol* · SLD / Schematic